Gerdes Tommy, Kirchhoff Maria, Lind Anne-Marie, Larsen Gitte Vestergaard, Schwartz Marianne, Lundsteen Claes
Department of Clinical Genetics, Rigshospitalet, DK-2100 Copenhagen Ø, Denmark.
Eur J Hum Genet. 2005 Feb;13(2):171-5. doi: 10.1038/sj.ejhg.5201307.
In routine prenatal diagnostics we used a commercial multiplex ligation-dependent probe amplification (MLPA) kit for aneuploidy screening for chromosomes 13, 18, 21, X and Y. We present the results of 1593 consecutive prenatal samples analysed and diagnosed prior to knowledge of the G-banding analysis during 8-month routine use of computer-assisted MLPA aneuploidy screening. In total, 27 aneuploidies were detected. There were no false positive results while two false negative results could be explained by a placental mosaicism and a partial monosomy, respectively. In total, 3.2% of the samples were inconclusive. We conclude that automatic computer assisted MLPA is a rapid, simple and reliable method for detection of aneuploidies in prenatal diagnostics.
在常规产前诊断中,我们使用了一种商业多重连接依赖探针扩增(MLPA)试剂盒对13、18、21、X和Y染色体进行非整倍体筛查。我们展示了在计算机辅助MLPA非整倍体筛查8个月的常规使用期间,在进行G带分析之前分析和诊断的1593例连续产前样本的结果。总共检测到27例非整倍体。没有假阳性结果,而两个假阴性结果分别可由胎盘嵌合体和部分单体性来解释。总共有3.2%的样本结果不确定。我们得出结论,自动计算机辅助MLPA是产前诊断中检测非整倍体的一种快速、简单且可靠的方法。