Rotteveel Liselotte J C, Proops David W, Ramsden Richard T, Saeed Shakeel R, van Olphen Adriaan F, Mylanus Emmanuel A M
Department of Otorhinolaryngology, University Medical Center, Nijmegen, The Netherlands.
Otol Neurotol. 2004 Nov;25(6):943-52. doi: 10.1097/00129492-200411000-00014.
To collect data from a large number of cochlear implant recipients with otosclerosis and to make an assessment of these patients' clinical characteristics, computed tomographic scans, surgical findings, and complications, and to quantify the occurrence of postoperative facial nerve stimulation.
Retrospective multicenter study.
Fifty-three patients with otosclerosis from four cochlear implant centers in the United Kingdom and The Netherlands were reviewed. Sixty surgical procedures were performed in these patients: 57 devices were placed in 56 ears.
The computed tomographic imaging demonstrated retrofenestral (cochlear) otosclerotic lesions in the majority of patients. Although not statistically significant, the extent of otosclerotic lesions on the computed tomographic scan as categorized in three types tends to be greater in patients with rapidly progressive hearing loss, in patients in whom there is surgically problematic insertion of the electrode array, and in patients with facial nerve stimulation. In four patients, revision surgery had to be performed. Twenty of 53 (38%) patients experienced facial nerve stimulation at various periods postoperatively.
Cochlear implant surgery in patients with otosclerosis can be challenging, with a relatively high number of partial insertions and misplacements of the electrode array demanding revision surgery. A very high proportion of patients experienced facial nerve stimulation mainly caused by the distal electrodes. This must be discussed with patients preoperatively.
收集大量耳硬化症人工耳蜗植入受者的数据,评估这些患者的临床特征、计算机断层扫描结果、手术发现及并发症,并对术后面神经刺激的发生率进行量化。
回顾性多中心研究。
对来自英国和荷兰四个人工耳蜗植入中心的53例耳硬化症患者进行了回顾性研究。这些患者共接受了60次手术:56耳植入了57个装置。
计算机断层扫描成像显示,大多数患者存在窗后(耳蜗)耳硬化病变。尽管无统计学意义,但计算机断层扫描中按三种类型分类的耳硬化病变范围,在听力快速下降的患者、电极阵列手术插入有问题的患者以及出现面神经刺激的患者中,往往更大。4例患者需进行翻修手术。53例患者中有20例(38%)在术后不同时期出现面神经刺激。
耳硬化症患者的人工耳蜗植入手术具有挑战性,电极阵列部分插入和错位的数量相对较多,需要进行翻修手术。很高比例的患者出现面神经刺激,主要由远端电极引起。术前必须与患者讨论这一情况。