Abstract

Haemoglobin (Hb) was entrapped in polysorbate 20 and then modified on a pyrolytic graphite electrode. Electrochemical studies revealed that a pair of stable and well-defined redox peaks attributed to the direct redox reaction of Hb could be observed in a phosphate buffer solution (pH 6.0). The anodic and cathodic peaks were located at -236 and -316 mV (versus a saturated calomel reference electrode) separately. The formal potential, E0', was linearly varied with pH in the range from 3.0 to 10.0 with a slope of -48.0 mV.pH-1. Moreover, the protein was capable of catalysing the reduction of H2O2. Accordingly, an unmediated biosensor for H2O2 was prepared with a linear range from 8.0x10(-7) to 1.0x10(-3) M. This biosensor exhibited good stability, sensitivity and reproducibility.