To describe clinical experiences with multi-channel cochlear implantation in patients with bilateral inner ear malformations.
Among 410 patients who received multi-channel cochlear implantations from 1996 to 2004 in Beijing Tongren Hospital, 82 patients were diagnosed with inner ear malformations and implanted. A retrospective analysis was performed about the surgical characteristics and mapping characteristics after implantation.
(1) All patients had auditory sensations. (2) Gusher was more common than the normal cochlear implantation. (3) The electrodes were inserted in the "cochleostomy" in full length of 80 Patients, but 2 pairs of electrodes remained outside of "cochleostomy" in 2 patients. (4) No serious complications occurred after implantation. (5) The impedance of the electrodes, the T level and C level were similar with the normal cochlear implantation. The results had no significant difference in compare with normal cochlear group (P > 0. 05). (6) The abilities of speech discrimination and spoken language were improved through rehabilitation.
The cochlear implantation can be performed safely in inner ear malformations. The outcome of hearing rehabilitation for patients with inner ear malformations are similar to those children with normal cochlear structure followed the multi-channel cochlear implantation.
描述双侧内耳畸形患者多通道人工耳蜗植入的临床经验。
在1996年至2004年于北京同仁医院接受多通道人工耳蜗植入的410例患者中,82例被诊断为内耳畸形并接受了植入。对植入后的手术特点和调机特点进行回顾性分析。
(1)所有患者均有听觉感受。(2)脑脊液误吸比正常人工耳蜗植入更常见。(3)80例患者电极在“蜗窗造口”处全长插入,但2例患者有2对电极留在“蜗窗造口”外。(4)植入后未发生严重并发症。(5)电极阻抗、T值和C值与正常人工耳蜗植入相似。与正常人工耳蜗组比较,结果无显著差异(P>0.05)。(6)通过康复训练,言语辨别能力和口语能力得到提高。
内耳畸形患者可安全地进行人工耳蜗植入。内耳畸形患者的听力康复效果与正常耳蜗结构的儿童接受多通道人工耳蜗植入后的效果相似。