Erten Hülya, Akarslan Zühre Zafersoy, Topuz Ozgür
Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey.
Quintessence Int. 2005 Jan;36(1):65-70.
The aim of this study was to evaluate the efficiency of Ultraspeed, Ektaspeed Plus, and Insight radiographic films, and radiovisiography in detecting approximal carious lesions.
Eighty approximal surfaces of 40 extracted human molars and premolars were evaluated. Radiographs of teeth blocks were taken with three different films and radiovisiography under standard conditions. The presence or absence of approximal caries was evaluated by three observers according to a five-point confidence scale. The actual status of each surface of the teeth was histologically determined from the teeth sections. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios of the imaging modalities were calculated, and observer responses were assessed with Kendall's tau and Spearman's rho tests.
The sensitivity values for Ultraspeed, Ektaspeed Plus, Insight, and radiovisiography were 0.39, 0.48, 0.45, and 0.49, respectively, while the specificity values were 0.91, 0.88, 0.84, and 0.90, respectively. The difference in detecting approximal carious lesions between the systems was not statistically significant.
This study suggests that there is no significant difference between the four imaging modalities in detecting approximal carious lesions.
本研究旨在评估超高速胶片、Ektaspeed Plus胶片、Insight射线胶片及口腔数字成像系统在检测邻面龋损方面的效率。
对40颗拔除的人类磨牙和前磨牙的80个邻面进行评估。在标准条件下,使用三种不同的胶片及口腔数字成像系统对牙块进行X线摄影。由三名观察者根据五点可信度量表评估邻面龋的有无。通过牙齿切片的组织学检查确定牙齿每个表面的实际状况。计算成像方式的灵敏度、特异度、阳性和阴性预测值以及似然比,并用肯德尔tau检验和斯皮尔曼等级相关系数检验评估观察者的反应。
超高速胶片、Ektaspeed Plus胶片、Insight胶片及口腔数字成像系统的灵敏度值分别为0.39、0.48、0.45和0.49,而特异度值分别为0.91、0.88、0.84和0.90。各系统在检测邻面龋损方面的差异无统计学意义。
本研究表明,四种成像方式在检测邻面龋损方面无显著差异。