Ab-interno neodymium:YAG versus erbium:YAG laser sclerostomies in a rabbit model.

作者信息

Hill R A, Ozler S A, Baerveldt G, Viscardi J J, Keates R H, Lee M, Harrington J A, Berns M W

机构信息

Department of Ophthalmology, University of California, Irvine 92717.

出版信息

Ophthalmic Surg. 1992 Mar;23(3):192-7.

PMID:1574289
Abstract

This study was undertaken to determine whether thermally-induced tissue necrosis was a factor in ab-interno contact-laser sclerostomy failure. A rabbit model was used to compare the continuous-wave Neodymium (Nd):YAG with the pulsed Erbium (Er):YAG laser with respect to such failure. Laser energy was focused into a fused-silica fiber optic (400 microns) for the Nd:YAG laser (12 W; 3 to 5 seconds), and into a single-crystal, uncladded sapphire fiber optic (250 microns) for the Er:YAG laser (7 to 8 mJ; 250 microseconds; 6 to 8 pulses). The Nd:YAG and Er:YAG lasers required from 21 to 35 J and from 42 to 64 mJ, respectively, to create the sclerostomies. Filtering blebs and intraocular pressure reduction lasted longer (log-rank test; P less than .03) and surgical complications were fewer in the Er:YAG group than in the Nd:YAG group. By creating sclerostomies with minimal thermal damage, the Er:YAG laser may offer significant clinical advantages over lasers producing larger thermal effects.