H E Hai-cheng, Zhang Guang-xia, Huang Zhi-rong, He Xi-wen, Huang Xin-ping, Yang Ti-shao
Department of Chemistry, Nankai University, Tianjin 300071, China.
Guang Pu Xue Yu Guang Pu Fen Xi. 2004 Jul;24(7):887-9.
A method for the determination of Al, Fe, Ca, Cr, Mn, Ni, Si and Ti elements in ferrum aluminum silicon alloy by inductively coupled plasma atomic emission spectrometry (ICP-AES) was described. The influence of ICP-AES operating conditions, sample dissolution methods and spectral lines were studied. The preferable experimental conditions were examined, and the influences of coexistent elements on the signals were investigated. The method was applied to the determination of elements in ferrum aluminum silicon alloy samples, and the measured results were in good agreement with the recommended values of the standard steel. The detection limits of the method were 0.029 microg x mL(-1) for Al, 0.004 microg x mL(-1) for Fe, 0.0075 microg x mL(-1) for Ca, 0.0015 microg x mL(-1) for Cr, 0.0009 microg x mL(-1) for Mn, 0.0027 microg x mL(-1) for Ni, 0.045 microg x mL(-1) for Si and 0.003 microg x mL(-1) for Ti. The relative standard deviation (n=6) of this method was between 0.3%-1.8%, and the recoveries by standard addition were in the range of 96.7%-102.9%. The method was used to determine the amount of silicon in alloy samples with satisfactory results, which agreed with those by the standard gravimetry. The method is characterized by good precision, easy operation and convenience to apply.
介绍了一种用电感耦合等离子体原子发射光谱法(ICP - AES)测定铁铝硅合金中铝、铁、钙、铬、锰、镍、硅和钛元素的方法。研究了ICP - AES工作条件、样品溶解方法和谱线的影响。考察了最佳实验条件,研究了共存元素对信号的影响。该方法应用于铁铝硅合金样品中元素的测定,测定结果与标准钢推荐值吻合良好。该方法的检出限为:铝0.029μg·mL⁻¹、铁0.004μg·mL⁻¹、钙0.0075μg·mL⁻¹、铬0.0015μg·mL⁻¹、锰0.0009μg·mL⁻¹、镍0.0027μg·mL⁻¹、硅0.045μg·mL⁻¹、钛0.003μg·mL⁻¹。该方法的相对标准偏差(n = 6)在0.3% - 1.8%之间,加标回收率在96.7% - 102.9%范围内。该方法用于测定合金样品中的硅含量,结果令人满意,与标准重量法测定结果一致。该方法具有精密度好、操作简便、应用方便的特点。