Suppr超能文献

A kinetic model and its parameter estimation for the process of binding copper to human serum albumin by a voltammetric method.

作者信息

Zhong Kejun, Xia Jianjun, Wei Wanzhi, Hu Yanbo, Tao Han, Liu Wei

机构信息

State Key Laboratory of Chem/Biosensing and Chemometrics College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, PR China.

出版信息

Anal Bioanal Chem. 2005 Apr;381(8):1552-7. doi: 10.1007/s00216-005-3104-9. Epub 2005 Mar 22.

Abstract

Linear sweep anodic stripping voltammetry was applied to determine the concentration of free copper ions in the process of binding copper to human serum albumin (HSA) on the mercaptoethane sulfonate modified gold electrode surface. A kinetic model of two consecutive steps for the process of binding copper to HSA was first proposed on the basis of the electrochemical results and compared with a parallel kinetic response model by using residual analysis. The experimental data of the stripping peak currents with time was fitted according to the model and the kinetic parameters, binding rate constants, k1 and k2, were estimated to be 0.411 and 0.055 min(-1), respectively.