Barai Sukanta, Bandopadhayaya G P, Patel C D, Rathi Manish, Kumar R, Bhowmik D, Gambhir S, Singh N Gopendro, Malhotra A, Gupta K D
Department of Nuclear Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India.
Nephron Physiol. 2005;101(1):p21-6. doi: 10.1159/000086038. Epub 2005 May 27.
Until now, a normal reference range for glomerular filtration rate (GFR) in adult Indian potential kidney donors has not been determined and values from a western population are being used as reference.
To determine the reference range of GFR in healthy adult Indian potential kidney donors.
GFR was measured in 610 (250 male, 360 female, average age 35.16 years) healthy potential kidney donors using the 99mTc-DTPA (diethylenetriamine pentaacetic acid) two-plasma sample method of Russell.
The mean body surface area (BSA)-normalized GFR value of a young healthy Indian adult potential kidney donor was calculated as 81.4 +/- 19.4 ml/min/1.73 m2 BSA--for males it was 82.3 +/- 21.3 ml/min/1.73 m2 BSA and for females 80.8 +/- 18.1 ml/min/1.73 m2 BSA. There was no significant difference between derived mean GFR values in males and females with a p value of 0.37.
The normal GFR value for the healthy Indian adult potential kidney donor appears to be much lower than the accepted value for a western population. The mean GFR value of a young healthy Indian adult potential kidney donor is 81.4 +/- 19.4 ml/min/1.73 m2 BSA, which is significantly different from the normal value of 109-125 ml/min derived from a western population. These findings might be useful in deciding on a suitable kidney donor in an Indian context.
迄今为止,尚未确定成年印度潜在肾脏捐赠者肾小球滤过率(GFR)的正常参考范围,目前使用的是西方人群的参考值。
确定健康成年印度潜在肾脏捐赠者的GFR参考范围。
采用Russell的99mTc - DTPA(二乙三胺五乙酸)双血浆样本法,对610名(250名男性,360名女性,平均年龄35.16岁)健康潜在肾脏捐赠者进行GFR测量。
年轻健康的成年印度潜在肾脏捐赠者经平均体表面积(BSA)标准化后的GFR值计算为81.4±19.4 ml/min/1.73 m2 BSA,男性为82.3±21.3 ml/min/1.73 m2 BSA,女性为80.8±18.1 ml/min/1.73 m2 BSA。男性和女性的平均GFR值之间无显著差异,p值为0.37。
健康成年印度潜在肾脏捐赠者的正常GFR值似乎远低于西方人群的公认值。年轻健康的成年印度潜在肾脏捐赠者的平均GFR值为81.4±19.4 ml/min/1.73 m2 BSA,与西方人群得出的109 - 125 ml/min的正常值有显著差异。这些发现可能有助于在印度背景下确定合适的肾脏捐赠者。