Suppr超能文献

采用不同克氏针和张力钢丝带配置稳定横向截骨术的四点弯曲强度。

Four-point bending strength of transverse osteotomies stabilized with various Kirschner wire and tension wire band configurations.

作者信息

Pehlivan O, Kiral A, Mahirogullari M, Koksal O, Kaplan H

机构信息

Department of Orthopaedics and Traumatology, Gulhane Military Medical Faculty, Haydarpasa Training Hospital, Istanbul, Turkey.

出版信息

J Hand Surg Br. 2005 Aug;30(4):428-31. doi: 10.1016/j.jhsb.2005.04.002.

Abstract

Four different fixation configurations of K-wires of two different diameters were used to stabilize a transverse osteotomy in chicken humerus bones. Four-point bending was applied to these to assess their apex dorsal bending rigidity. The configurations of K-wires included intramedullary, crossed and two with different tension wire band designs. One of these consisted of two transverse K-wires which did not cross the fracture line, around which the tension wire band was placed. The results showed that there was no statistical significance between the two different tension band wiring techniques and that both were superior to the intramedullary and crossed K-wire fixation techniques.

摘要

使用两种不同直径的克氏针的四种不同固定构型来稳定鸡肱骨的横向截骨术。对这些构型施加四点弯曲以评估其顶点背侧弯曲刚度。克氏针的构型包括髓内、交叉以及两种不同张力钢丝带设计。其中一种由两根不穿过骨折线的横向克氏针组成,张力钢丝带置于其周围。结果表明,两种不同的张力带钢丝技术之间没有统计学意义,并且两者均优于髓内和交叉克氏针固定技术。