Suppr超能文献

18F-氟脱氧葡萄糖正电子发射断层扫描用于淋巴瘤分期中骨髓浸润评估的荟萃分析

18F-FDG PET for evaluation of bone marrow infiltration in staging of lymphoma: a meta-analysis.

作者信息

Pakos Emilios E, Fotopoulos Andreas D, Ioannidis John P A

机构信息

Clinical and Molecular Epidemiology Unit, Department of Hygiene and Epidemiology, University of Ioannina School of Medicine, Ioannina 45110, Greece.

出版信息

J Nucl Med. 2005 Jun;46(6):958-63.

Abstract

UNLABELLED

The ability of PET with (18)F-FDG to evaluate bone marrow infiltration in patients with lymphoma has been a matter of extensive investigation with controversial results. Therefore, we aimed to evaluate systematically, with a meta-analysis, the diagnostic performance of (18)F-FDG PET in this setting.

METHODS

Relevant studies were identified with MEDLINE and EMBASE searches (last update, August 2004). Data on the diagnostic performance of (18)F-FDG PET were combined quantitatively across eligible studies. We estimated weighted summary sensitivities and specificities, summary receiver-operating-characteristic (SROC) curves, and weighted summary likelihood ratios. We also conducted separate analyses according to various subgroups. Bone marrow biopsy (BMB) was used as the reference standard.

RESULTS

Thirteen eligible nonoverlapping studies, which enrolled a total of 587 patients, were included in the meta-analysis. The independent random-effects weighted estimates of sensitivity and specificity against BMB were 51% (95% confidence interval [CI], 38%-64%) and 91% (95% CI, 85%-95%), respectively. Results were consistent in the SROC curve: a sensitivity of 51% corresponds to a specificity of 92%, whereas a specificity of 91% corresponds to a sensitivity of 55%. The weighted positive likelihood ratio (LR+) was 5.75 (95% CI, 348-9.48) and the negative likelihood ratio (LR-) was 0.67 (95% CI, 0.55-0.82). Six of 12 patients with positive (18)F-FDG PET and negative initial biopsy were found to have bone marrow involvement when biopsy was performed at the sites with positive imaging signals. Subgroup analyses showed better sensitivity in patients with Hodgkin's disease and in aggressive histologic types of non-Hodgkin's lymphoma than in patients with less aggressive histologic types and in studies using unilateral BMB compared with those using bilateral biopsy.

CONCLUSION

This meta-analysis showed that (18)F-FDG PET has good, but not excellent, concordance with the results of BMB for the detection of bone marrow infiltration in the staging of patients with lymphoma. (18)F-FDG PET may complement the results of BMB and its performance may vary according to the type of lymphoma.

摘要

未标记

利用(18)F - FDG进行正电子发射断层显像(PET)评估淋巴瘤患者骨髓浸润情况的能力一直是广泛研究的课题,但其结果存在争议。因此,我们旨在通过荟萃分析系统评估(18)F - FDG PET在这种情况下的诊断性能。

方法

通过检索MEDLINE和EMBASE(最后更新时间为2004年8月)来确定相关研究。对符合条件的研究中(18)F - FDG PET诊断性能的数据进行定量合并。我们估计了加权汇总敏感性和特异性、汇总接受者操作特征(SROC)曲线以及加权汇总似然比。我们还根据不同亚组进行了单独分析。骨髓活检(BMB)用作参考标准。

结果

13项符合条件且不重叠的研究纳入了荟萃分析,这些研究共纳入587例患者。与BMB相比,敏感性和特异性的独立随机效应加权估计分别为51%(95%置信区间[CI],38% - 64%)和91%(95% CI,85% - 95%)。SROC曲线结果一致:敏感性为51%时特异性为92%,特异性为91%时敏感性为55%。加权阳性似然比(LR +)为5.75(95% CI,3.48 - 9.48),阴性似然比(LR -)为0.67(95% CI,0.55 - 0.82)。12例(18)F - FDG PET阳性但初始活检阴性患者中,有6例在对影像信号阳性部位进行活检时发现有骨髓受累。亚组分析显示,与侵袭性较低组织学类型的患者以及采用双侧活检的研究相比,霍奇金病患者和侵袭性组织学类型的非霍奇金淋巴瘤患者的敏感性更高。

结论

这项荟萃分析表明(18)F - FDG PET在检测淋巴瘤患者分期中的骨髓浸润方面与BMB结果具有良好但并非极佳的一致性。(18)F - FDG PET可补充BMB的结果,其性能可能因淋巴瘤类型而异。