Three experiments investigated whether background noise modified the startle blink reflex and prepulse inhibition (PPI). In Experiment 1 background noise was about 28 (ambient), 40, and 60 dB; in Experiments 2 and 3 background noise was ambient and 60 dB. Prepulses were 70-dB tones (Experiments 1 and 3) or a tactile stimulus (Experiment 2). Startle-eliciting stimuli were 94-dB noise (Experiments 1 and 2) or an airpuff to the face (Experiment 3). Prepulses were presented at stimulus onset asynchronies of 30, 60, 120, 240, and 2000 ms relative to the startle-eliciting stimulus. Background noise of 60 dB had no effect on control reflexes, whereas 40-dB background noise increased control reflexes. Background noise decreased PPI, but only when an acoustic stimulus was used as prepulse. In sum, the findings show that background noise reduces the signal-to-noise ratio of acoustic prepulses and decreases their modulatory effect on the startle reflex.
三项实验研究了背景噪声是否会改变惊吓眨眼反射和前脉冲抑制(PPI)。在实验1中,背景噪声分别约为28(环境噪声)、40和60分贝;在实验2和3中,背景噪声为环境噪声和60分贝。前脉冲为70分贝的音调(实验1和3)或触觉刺激(实验2)。引发惊吓的刺激为94分贝的噪声(实验1和2)或向面部吹气(实验3)。前脉冲在相对于引发惊吓刺激的刺激起始异步时间为30、60、120、240和2000毫秒时呈现。60分贝的背景噪声对对照反射没有影响,而40分贝的背景噪声增加了对照反射。背景噪声降低了PPI,但仅当使用声学刺激作为前脉冲时。总之,研究结果表明,背景噪声降低了声学前脉冲的信噪比,并降低了它们对惊吓反射的调节作用。