The effects of high-Dk rigid contact lens center thickness, material permeability, and blinking on the oxygen uptake of the human cornea.

作者信息

Gardner Hope Patterson, Fink Barbara A, Mitchell Lynn G, Hill Richard M

机构信息

The Ohio State University College of Optometry, Columbus, Ohio 43210, USA.

出版信息

Optom Vis Sci. 2005 Jun;82(6):459-66. doi: 10.1097/01.opx.0000168562.64251.66.

Abstract

PURPOSE

The human corneal oxygen uptake responses associated with the static (nonblinking) and dynamic (blinking) wear of five rigid gas-permeable materials with high oxygen permeabilities were determined for three different center thicknesses and compared with the responses for the normal open eye and severe hypoxic stress (static wear of polymethylmethacrylate).

METHODS

Corneal oxygen uptake rates were measured with a Clark-type polarographic electrode during two sessions with each of 10 human subjects. Measurements were made on the right eye for the normal open eye (air) and after 5 minutes of static and dynamic wear of polymethylmethacrylate and five rigid gas-permeable contact lens materials: Fluoroperm 92 (paflufocon A, Dk = 92), Fluoroperm 151 (paflufocon D, Dk = 151), 1992 Menicon SF-P (melafocon A, Dk = 102), 1995 Menicon SF-P (melafocon A, Dk = 159), and Menicon Z (tisilfocon A, Dk = 163-250). Lenses were manufactured in three different center thicknesses (0.12, 0.16, and 0.20 mm), with all other parameters remaining constant. Repeated-measures analysis of variance was used and included lens material (five levels), blinking condition (two levels), and lens thickness (three levels) as within-subject effects.

RESULTS

Significant differences were found in corneal oxygen responses to lens material (p < 0.001) and lens thickness (p < 0.001), with lenses of lower oxygen permeability and thicker lenses being associated with higher oxygen uptake. No statistically significant differences were noted between static or dynamic wear of the lens materials (p = 0.59).

CONCLUSIONS

For those very high Dk rigid lens materials studied here, moderate changes in lens thickness or material permeability may result in modest differences in corneal hypoxic relief, whereas blinking results in no significant improvement to corneal oxygenation.

摘要

目的

针对三种不同中心厚度的五种具有高透氧性的硬性透气性材料,测定其在静态(不眨眼)和动态(眨眼)佩戴时的人角膜氧摄取反应,并与正常睁眼和严重低氧应激(聚甲基丙烯酸甲酯的静态佩戴)时的反应进行比较。

方法

在10名人类受试者的两个阶段中,使用Clark型极谱电极测量角膜氧摄取率。测量右眼在正常睁眼(空气环境)以及佩戴聚甲基丙烯酸甲酯和五种硬性透气性隐形眼镜材料(氟透92(帕氟康A,Dk = 92)、氟透151(帕氟康D,Dk = 151)、1992美尼康SF - P(美拉康A,Dk = 102)、1995美尼康SF - P(美拉康A,Dk = 159)和美尼康Z(替西康A,Dk = 163 - 250))5分钟后的静态和动态佩戴情况。镜片制作成三种不同的中心厚度(0.12、0.16和0.20毫米),其他所有参数保持不变。采用重复测量方差分析,将镜片材料(五个水平)、眨眼条件(两个水平)和镜片厚度(三个水平)作为受试者内效应。

结果

发现角膜对镜片材料(p < 0.001)和镜片厚度(p < 0.001)的氧反应存在显著差异,透氧性较低的镜片和较厚的镜片与较高的氧摄取相关。镜片材料的静态或动态佩戴之间未发现统计学上的显著差异(p = 0.59)。

结论

对于此处研究的那些极高Dk值的硬性镜片材料,镜片厚度或材料透氧性的适度变化可能会导致角膜低氧缓解方面的适度差异,而眨眼对角膜氧合没有显著改善。