Patters Mark R, Bland Paul S, Shiloah Jacob, Blankenship Jane Anne, Scarbecz Mark
Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38163, USA.
J Int Acad Periodontol. 2005 Jul;7(3):80-9.
An examiner-blinded, randomized, parallel, three-cell, controlled clinical trial was conducted to compare the efficacy of a new powered toothbrush (Hydrabrush) to that of two presently marketed power brushes (Oral-B and Sonicare) in reducing stain, supragingival plaque, gingivitis and the signs of periodontitis while monitoring safety.
One hundred ten subjects were randomly assigned to three groups (35--Oral-B group, 36--Sonicare group, and 39--Hydrabrush group). Subjects were instructed to use the assigned powered toothbrush according to the manufacturer's instructions for 2-minutes duration twice per day. Clinical examinations conducted at baseline and at weeks 4, 8, and 12 included the following parameters: (1) oral tissues; (2) staining; (3) plaque index; (4) gingivitis; (5) probing depth; (6) clinical attachment loss; and 7) bleeding on probing.
The results showed that the body intensity and extent of stain and the gingival intensity and extent of stain at 8 and 12 weeks, respectively, were significantly less in the Hydrabrush group compared with the Sonicare group. The modified gingival index (MGI) in all groups significantly decreased over the 12 weeks. However, the groups did not differ from each other statistically. At 4, 8 and 12 weeks, the Hydrabrush group had statistically significantly less plaque than the Sonicare group. At 4 weeks, the Hydrabrush group had statistically significantly lower mean probing depth than both the Oral-B and Sonicare groups. At 8 and 12 weeks, the Hydrabrush group had statistically significantly lower mean probing depths than the Sonicare group. With regard to mean percentage of sites with probing depth > or =4 mm, the Hydrabrush group had statistically significantly fewer sites > or =4 mm at 4, 8 and 12 weeks. Differences among the groups in clinical attachment loss at 4, 8 and 12 weeks were representative of small imbalances at baseline. No differences were seen among the treatment groups with regard to gingival recession and bleeding on probing.
With the exception of clinical attachment loss, all subject groups were balanced for all measured clinical parameters at baseline. Tooth stain became significantly less in the Hydrabrush group compared with the Sonicare group at 8 and 12 weeks. At all examinations, the Hydrabrush group had statistically significantly less plaque than the Sonicare group. At 4 weeks, the Hydrabrush group had statistically significantly lower mean probing depth than both the Oral-B and Sonicare groups, and at 8 and 12 weeks, the Hydrabrush group had statistically significantly lower mean probing depth than the Sonicare group. With regard to mean percentage of sites with probing depth > or =4 mm, the Hydrabrush group had statistically significantly fewer sites > or =4 mm when compared to the other two tested brushes at all examinations. No differences were seen among the treatment groups with regard to gingival recession and bleeding on probing and none of the tested brushes caused any adverse reactions.
开展了一项由检查者盲法、随机、平行、三单元对照临床试验,以比较一种新型电动牙刷(Hydrabrush)与两种市售电动牙刷(欧乐B和飞利浦声波震动牙刷)在减少牙菌斑、龈上菌斑、牙龈炎和牙周炎症状方面的疗效,并监测安全性。
110名受试者被随机分为三组(35名——欧乐B组,36名——飞利浦声波震动牙刷组,39名——Hydrabrush组)。指导受试者按照制造商的说明,每天使用指定的电动牙刷两次,每次持续2分钟。在基线、第4、8和12周进行的临床检查包括以下参数:(1)口腔组织;(2)染色情况;(3)菌斑指数;(4)牙龈炎;(5)探诊深度;(6)临床附着丧失;以及(7)探诊出血。
结果显示,与飞利浦声波震动牙刷组相比,Hydrabrush组在第8周和第12周时牙菌斑的总体强度和范围以及牙龈染色的强度和范围明显更小。在12周内,所有组的改良牙龈指数(MGI)均显著下降。然而,各组之间在统计学上并无差异。在第4、8和12周时,Hydrabrush组的菌斑在统计学上显著少于飞利浦声波震动牙刷组。在第4周时,Hydrabrush组的平均探诊深度在统计学上显著低于欧乐B组和飞利浦声波震动牙刷组。在第8周和第12周时,Hydrabrush组的平均探诊深度在统计学上显著低于飞利浦声波震动牙刷组。关于探诊深度≥4mm部位的平均百分比,Hydrabrush组在第4、8和12周时≥4mm的部位在统计学上显著更少。在第4、8和12周时,各组在临床附着丧失方面的差异代表了基线时的微小不平衡。在牙龈退缩和探诊出血方面,各治疗组之间未见差异。
除临床附着丧失外,所有受试者组在基线时所有测量的临床参数均保持平衡。与飞利浦声波震动牙刷组相比,Hydrabrush组在第8周和第12周时牙菌斑明显减少。在所有检查中,Hydrabrush组的菌斑在统计学上显著少于飞利浦声波震动牙刷组。在第4周时,Hydrabrush组的平均探诊深度在统计学上显著低于欧乐B组和飞利浦声波震动牙刷组,在第8周和第12周时,Hydrabrush组的平均探诊深度在统计学上显著低于飞利浦声波震动牙刷组。关于探诊深度≥4mm部位的平均百分比,在所有检查中,与其他两种测试牙刷相比,Hydrabrush组≥4mm的部位在统计学上显著更少。在牙龈退缩和探诊出血方面,各治疗组之间未见差异,且所有测试牙刷均未引起任何不良反应。