Hill J C
Department of Ophthalmology, Medical School, University of Cape Town, South Africa.
Ophthalmic Surg. 1992 May;23(5):320-4.
The results of 36 patients who underwent penetrating keratoplasty with transscleral fixation of a posterior chamber intraocular lens are reviewed. A 13.75-millimeter "Revlens," which has the configuration of an open-loop anterior chamber lens, was used in all of the cases and gave good stability in the ciliary sulcus. The 10-0 Prolene sutures used to secure the implants were burrowed through the sclera and exited sufficiently far from the limbus to be adequately covered by Tenon's capsule and conjunctiva. No sutures eroded through the conjunctiva or needed to be removed. Two grafts became opaque, one from rejection and the other from uncontrolled glaucoma. No vitreous hemorrhage or retinal detachment occurred. Ten patients (27.8%) had cystoid macular edema diagnosed either before or after surgery; three had age-related macular degeneration; and two had traumatic macular scars. Sixteen eyes (44.4%) had final visual acuities of 20/40 or better and 25 (69.4%) saw 20/200 or better. Mean follow up was 16.8 months (range, 9 to 36 months).
回顾了36例行穿透性角膜移植术并经巩膜固定后房型人工晶状体植入术患者的结果。所有病例均使用了13.75毫米的“Revlens”,其结构为开环前房型人工晶状体,在睫状沟内具有良好的稳定性。用于固定植入物的10-0聚丙烯缝线穿过巩膜,从距角膜缘足够远的位置穿出,以便被眼球筋膜囊和结膜充分覆盖。没有缝线穿出结膜或需要拆除。两片移植片变得混浊,一片因排斥反应,另一片因未控制的青光眼。未发生玻璃体出血或视网膜脱离。10例患者(27.8%)在手术前或手术后被诊断为黄斑囊样水肿;3例患有年龄相关性黄斑变性;2例有外伤性黄斑瘢痕。16只眼(44.4%)的最终视力达到20/40或更好,25只眼(69.4%)的视力达到20/200或更好。平均随访时间为16.8个月(范围9至36个月)。