Cademartiri Filippo, Mollet Nico R, van der Lugt Aad, McFadden Eugene P, Stijnen Theo, de Feyter Pim J, Krestin Gabriel P
Department of Radiology, Erasmus Medical Center, Dr Molewaterplein 40, 3015GD Rotterdam, the Netherlands.
Radiology. 2005 Aug;236(2):661-5. doi: 10.1148/radiol.2362040468.
The institutional review board approved this study, and all patients gave written informed consent. One hundred twenty-five patients scheduled to undergo retrospectively electrocardiographically gated 16-detector row computed tomographic coronary angiography were prospectively randomized into the following five groups with respect to the intravenous administration of a 140-mL bolus of contrast material at 4 mL/sec: group 1 (iohexol [300 mg of iodine per milliliter]), group 2 (iodixanol [320 mg I/mL]), group 3 (iohexol [350 mg I/mL]), group 4 (iomeprol [350 mg I/mL]), and group 5 (iomeprol [400 mg I/mL]). Attenuation was measured in the descending aorta and coronary arteries. One-way analysis of variance was used to compare groups. Mean attenuation values in the descending aorta were significantly (P < .05) lower in group 1 and higher in group 5 compared with the mean values in the other three groups. The same pattern was observed in the coronary arteries. Contrast materials with higher iodine concentrations yield significantly higher attenuation in the descending aorta and coronary arteries.
该研究获得了机构审查委员会的批准,所有患者均签署了书面知情同意书。125例计划接受回顾性心电门控16排螺旋CT冠状动脉造影的患者,根据以4 mL/秒的速度静脉注射140 mL造影剂推注量,被前瞻性随机分为以下五组:第1组(碘海醇[每毫升含300 mg碘]),第2组(碘克沙醇[每毫升含320 mg碘]),第3组(碘海醇[每毫升含350 mg碘]),第4组(碘美普尔[每毫升含350 mg碘]),第5组(碘美普尔[每毫升含400 mg碘])。测量降主动脉和冠状动脉的衰减值。采用单因素方差分析对各组进行比较。与其他三组的平均值相比,第1组降主动脉的平均衰减值显著较低(P <.05),第5组则较高。冠状动脉也观察到相同的模式。碘浓度较高的造影剂在降主动脉和冠状动脉中产生的衰减明显更高。