Suppr超能文献

用于拉曼光谱在线监测的采样技术比较

Comparison of sampling techniques for in-line monitoring using Raman spectroscopy.

作者信息

Wikström Håkan, Lewis Ian R, Taylor Lynne S

机构信息

Department of Industrial and Physical Pharmacy, School of Pharmacy, Purdue University, West Lafayette, Indiana 47907, USA.

出版信息

Appl Spectrosc. 2005 Jul;59(7):934-41. doi: 10.1366/0003702054411553.

Abstract

Raman spectroscopy is currently of interest as a process monitoring tool for pharmaceutical unit operations. In this study, the performance characteristics of Raman spectrometers with different sampling optics have been investigated in the context of process monitoring, with emphasis being placed on assessing homogeneity in powder blends and following changes in solid-state form during wet granulation. A novel large spot non-contact Raman sampling device was compared with a traditional small spot size non-contact sampling device and an immersion probe. The large spot non-contact optics provided significant advantages over the standard systems both as a result of the enhanced sampling volume and because of the greater robustness of the system to fluctuations in the sampling distance during the wet granulation process.

摘要

拉曼光谱作为制药单元操作的过程监测工具,目前备受关注。在本研究中,已在过程监测的背景下研究了具有不同采样光学器件的拉曼光谱仪的性能特征,重点是评估粉末混合物的均匀性以及跟踪湿法制粒过程中固态形式的变化。将一种新型的大光斑非接触式拉曼采样装置与传统的小光斑尺寸非接触式采样装置和浸入式探头进行了比较。大光斑非接触式光学器件由于采样体积增加以及系统在湿法制粒过程中对采样距离波动具有更高的稳健性,因此相对于标准系统具有显著优势。