A simple, sensitive and selective liquid chromatography coupled with electrospray ionization mass spectrometry (LC/ESI/MS) method for determination of limonin (LM) in rat plasma has been developed and validated. The method had advantages of a single liquid-liquid extraction with ether and high sensitivity. Analyses were conducted at a flow rate of 0.2 ml/min by a gradient elution. The detection utilized selected ion monitoring in the negative ion mode at m/z 460.00 and 423.15 for the deprotonated molecular ions of LM and the internal standard, respectively. The quantitation limit for LM in rat plasma was 1.0 ng/ml. The linearity was also excellent over the concentration range of 1.9-500 ng/ml of LM. The intra- and inter-day precision (relative standard deviation (R.S.D.%)) was lower than 10% and accuracy ranged from 90 to 110%, showing a good reproducibility. This developed method was successfully applied to analysis of LM in biological fluids.

摘要

已开发并验证了一种简单、灵敏且具有选择性的液相色谱-电喷雾电离质谱联用(LC/ESI/MS)方法,用于测定大鼠血浆中的柠檬苦素(LM)。该方法具有用乙醚进行单次液液萃取且灵敏度高的优点。分析以0.2 ml/min的流速通过梯度洗脱进行。检测在负离子模式下采用选择离子监测,分别对LM和内标物的去质子化分子离子在m/z 460.00和423.15处进行监测。大鼠血浆中LM的定量限为1.0 ng/ml。在1.9 - 500 ng/ml的LM浓度范围内线性也非常好。日内和日间精密度(相对标准偏差(R.S.D.%))低于10%,准确度在90%至110%之间,显示出良好的重现性。所开发的该方法成功应用于生物流体中LM的分析。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验