Mersa Berkan, Ağir Hakan, Aydin Atakan, Sen Cenk
Plastic and Reconstructive Surgery, Medicine Faculty of Kocaeli University, Kocaeli, Turkey.
Kulak Burun Bogaz Ihtis Derg. 2004;13(5-6):103-11.
In this study, we compared expanded polytetrafluoroethylene (ePTFE) tube with autogenous vein as an alternative conduit material in a rat sciatic nerve model.
Thirty Wistar albino rats were assigned to three groups equal in number. A 1-cm defect was created in the right sciatic nerve of each rat. In group I (control), the nerve gap was repaired with autogenous nerve graft. In group II and III, the defects were bridged with autogenous vein graft and ePTFE tube, respectively. At 30 and 90 days, five rats from each group were subjected to inspection of feet for pressure sores, walking tract analysis, electrophysiological and histomorphological studies, and gastrocnemius muscle studies.
At 90 days, the mean gastrocnemius index in the nerve graft group (48.5+/-3) was statistically different from those of the autogenous vein (31.2+/-6) and ePTFE (35.3+/-8) groups (p<0.05). The mean myelinated axonal counts were 239+/-35, 164+/-34, and 145+/-31 in the nerve graft, vein graft, and ePTFE graft groups, respectively. The nerve graft group results were significantly better than the other groups (p<0.05). There were no significant differences in sciatic function index and electrophysiology results. The differences between the autogenous vein graft and ePTFE were not significant for any research parameters.
It was experimentally demonstrated that ePTFE tube could be considered an alternative to autogenous vein graft to bridge small nerve defects.
在本研究中,我们在大鼠坐骨神经模型中比较了膨体聚四氟乙烯(ePTFE)管与自体静脉作为替代导管材料的情况。
将30只Wistar白化大鼠平均分为三组。在每只大鼠的右侧坐骨神经上制造一个1厘米的缺损。在第一组(对照组)中,用自体神经移植物修复神经间隙。在第二组和第三组中,分别用自体静脉移植物和ePTFE管桥接缺损。在30天和90天时,对每组的五只大鼠进行足部压疮检查、行走轨迹分析、电生理和组织形态学研究以及腓肠肌研究。
在90天时,神经移植物组的平均腓肠肌指数(48.5±3)与自体静脉组(31.2±6)和ePTFE组(35.3±8)在统计学上有差异(p<0.05)。神经移植物组、静脉移植物组和ePTFE移植物组的平均有髓轴突计数分别为239±35、164±34和145±31。神经移植物组的结果明显优于其他组(p<0.05)。坐骨神经功能指数和电生理结果没有显著差异。自体静脉移植物和ePTFE之间在任何研究参数上的差异均不显著。
实验证明,ePTFE管可被视为桥接小神经缺损的自体静脉移植物的替代品。