Suppr超能文献

PETRRA正电子相机:物理评估的设计、特性及结果

The PETRRA positron camera: design, characterization and results of a physical evaluation.

作者信息

Divoli A, Flower M A, Erlandsson K, Reader A J, Evans N, Meriaux S, Ott R J, Stephenson R, Bateman J E, Duxbury D M, Spill E J

机构信息

Physics Department, Royal Marsden Hospital/Institute of Cancer Research, Downs Road, Sutton, Surrey, SM2 5PT, UK.

出版信息

Phys Med Biol. 2005 Sep 7;50(17):3971-88. doi: 10.1088/0031-9155/50/17/004. Epub 2005 Aug 11.

Abstract

The PETRRA positron camera is a large-area (600 mm x 400 mm sensitive area) prototype system that has been developed through a collaboration between the Rutherford Appleton Laboratory and the Institute of Cancer Research/Royal Marsden Hospital. The camera uses novel technology involving the coupling of 10 mm thick barium fluoride scintillating crystals to multi-wire proportional chambers filled with a photosensitive gas. The performance of the camera is reported here and shows that the present system has a 3D spatial resolution of approximately 7.5 mm full-width-half-maximum (FWHM), a timing resolution of approximately 3.5 ns (FWHM), a total coincidence count-rate performance of at least 80-90 kcps and a randoms-corrected sensitivity of approximately 8-10 kcps kBq(-1) ml. For an average concentration of 3 kBq ml(-1) as expected in a patient it is shown that, for the present prototype, approximately 20% of the data would be true events. The count-rate performance is presently limited by the obsolete off-camera read-out electronics and computer system and the sensitivity by the use of thin (10 mm thick) crystals. The prototype camera has limited scatter rejection and no intrinsic shielding and is, therefore, susceptible to high levels of scatter and out-of-field activity when imaging patients. All these factors are being addressed to improve the performance of the camera. The large axial field-of-view of 400 mm makes the camera ideally suited to whole-body PET imaging. We present examples of preliminary clinical images taken with the prototype camera. Overall, the results show the potential for this alternative technology justifying further development.

摘要

PETRRA正电子相机是一个大面积(敏感区域为600毫米×400毫米)的原型系统,它是由卢瑟福·阿普尔顿实验室与癌症研究所/皇家马斯登医院合作开发的。该相机采用了新技术,即将10毫米厚的氟化钡闪烁晶体与充满光敏气体的多丝正比室耦合。本文报道了该相机的性能,结果表明当前系统的三维空间分辨率约为7.5毫米半高宽(FWHM),时间分辨率约为3.5纳秒(FWHM),总符合计数率性能至少为80 - 90千计数每秒,随机校正灵敏度约为8 - 10千计数每秒每贝克勒尔每毫升。对于患者体内预期的平均浓度3贝克勒尔每毫升,结果表明,对于当前的原型相机,约20%的数据将是真实事件。目前,计数率性能受过时的相机外读出电子设备和计算机系统限制,灵敏度受薄(10毫米厚)晶体的使用限制。原型相机的散射剔除能力有限且没有固有屏蔽,因此在对患者成像时容易受到高水平散射和视野外活动的影响。所有这些因素都在得到解决以提高相机性能。400毫米的大轴向视野使该相机非常适合全身正电子发射断层显像(PET)成像。我们展示了用原型相机拍摄的初步临床图像示例。总体而言,结果显示了这种替代技术的潜力,证明值得进一步开发。

相似文献

1
The PETRRA positron camera: design, characterization and results of a physical evaluation.
Phys Med Biol. 2005 Sep 7;50(17):3971-88. doi: 10.1088/0031-9155/50/17/004. Epub 2005 Aug 11.
5
A four-layer attenuation compensated PET detector based on APD arrays without discrete crystal elements.
Phys Med Biol. 2005 Sep 7;50(17):4187-207. doi: 10.1088/0031-9155/50/17/019. Epub 2005 Aug 24.
6
Design of a very high-resolution small animal PET scanner using a silicon scatter detector insert.
Phys Med Biol. 2007 Aug 7;52(15):4653-77. doi: 10.1088/0031-9155/52/15/019. Epub 2007 Jul 17.
10
Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.
Phys Med Biol. 2006 May 7;51(9):N199-204. doi: 10.1088/0031-9155/51/9/N04. Epub 2006 Apr 19.