To investigate the influence of other substances used intraoperatively in vitreoretinal surgery on the emulsification of silicone oil in patients' eyes.
Gas chromatography coupled mass spectroscopy of the headspace (GC/MS/HS) was used to detect volatile compounds in silicone oil samples explanted from patients qualitatively as well as quantitatively. Surface and interfacial tensions of the explanted samples were measured using the pendent drop technique.
Some samples of nonemulsified explanted silicone oil were not different in their content of volatile substances measured by GC-MS/HS. In all explanted samples of emulsified silicone oil volatile substances could be detected, which do not exist or are at the detection limit in native silicone oil for ophthalmic use. The majority of contaminants are heavy liquids, cleaning substances, and oligosiloxanes.
The contact of silicone oil with all types of substances should be reduced to a minimum. Reuse of tubing sets must be avoided. If a direct exchange between heavy liquids and silicone oil seems necessary, turbulence at the interfaces must be avoided and the contact time between these two endotamponades must be kept as short as possible. If these precautions are obeyed, the risk of emulsification of silicone oil used as an ocular endotamponade can be significantly reduced, down to the influence of individual patients' conditions.
研究玻璃体视网膜手术中术中使用的其他物质对患者眼内硅油乳化的影响。
采用顶空气相色谱 - 质谱联用(GC/MS/HS)对从患者体内取出的硅油样品中的挥发性化合物进行定性和定量检测。使用悬滴法测量取出样品的表面张力和界面张力。
一些未乳化的取出硅油样品,通过GC - MS/HS测量的挥发性物质含量没有差异。在所有乳化硅油的取出样品中都能检测到挥发性物质,而这些物质在用于眼科的天然硅油中不存在或处于检测限。大多数污染物是重液体、清洁物质和低聚硅氧烷。
应将硅油与所有类型物质的接触降至最低。必须避免重复使用管路装置。如果似乎有必要在重液体和硅油之间直接交换,必须避免界面处的湍流,并且这两种眼内填充剂之间的接触时间必须尽可能短。如果遵守这些预防措施,用作眼内填充剂的硅油乳化风险可显著降低,直至个体患者状况的影响。