Pavlik Attila, Hidas Péter, Tállay András, Toman József, Berkes István
National Institute for Sports Medicine, Department of Sports Surgery, Budapest, Hungary.
Am J Sports Med. 2006 Feb;34(2):220-5. doi: 10.1177/0363546505279920. Epub 2005 Oct 6.
The security of the graft fixation is an important factor of anterior cruciate ligament reconstruction, especially in the early postoperative period.
The femoral press-fit fixation technique is a safe, alternative technique for the fixation of the bone-patellar tendon-bone graft.
Case series; Level of evidence, 4.
Between January 1, 1998, and June 30, 2002, 285 patients, with a mean age of 29.1 years, underwent operation and observation in our department. All patients had arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft with femoral press-fit and tibial interference screw fixation. The mean follow-up period was 35.8 months (range, 24-77 months). During each patient's evaluation, a physical examination, a subjective evaluation, the International Knee Documentation Committee and Lysholm scores, KT-1000 arthrometer testing, and radiological evaluation were performed. The paired Student t test or chi(2) test was used for statistical analysis.
According to the International Knee Documentation Committee score, 241 patients (85%) had good (46 normal and 195 nearly normal) results, whereas 39 patients had abnormal and 5 patients had severely abnormal overall results. The preoperative mean Lysholm score was 63.5 +/- 12.7 points. At the final examination, the mean value was 93.5 +/- 7.8 points (P < .01). One hundred ninety-seven athletes could return to their previous sports activity level, whereas 13 patients gave up their sports career. The KT-1000 arthrometer results showed a side-to-side difference of 1.91 +/- 2.1 mm at the maximum manual strength tests.
The femoral press-fit fixation is an alternative fixation method for the bone-patellar tendon-bone graft and provides good stability for the anterior cruciate ligament reconstruction. The use of press-fit fixation technique avoids most interference screw or other hardware-induced complications at the femoral side.
移植物固定的安全性是前交叉韧带重建的一个重要因素,尤其是在术后早期。
股骨压配固定技术是一种用于固定骨-髌腱-骨移植物的安全的替代技术。
病例系列;证据等级,4级。
在1998年1月1日至2002年6月30日期间,285例平均年龄为29.1岁的患者在我科接受手术和观察。所有患者均接受关节镜下前交叉韧带重建,采用骨-髌腱-骨移植物,股骨压配及胫骨界面螺钉固定。平均随访期为35.8个月(范围24 - 77个月)。在对每位患者的评估过程中,进行了体格检查、主观评估、国际膝关节文献委员会(IKDC)和Lysholm评分、KT-1000关节测径仪测试以及影像学评估。采用配对t检验或卡方检验进行统计学分析。
根据IKDC评分,241例患者(85%)结果良好(46例正常,195例接近正常),而39例患者结果异常,5例患者总体结果严重异常。术前平均Lysholm评分为63.5±12.7分。在最后一次检查时,平均值为93.5±7.8分(P <.01)。197名运动员能够恢复到之前的运动活动水平,而13名患者放弃了他们的运动生涯。KT-1000关节测径仪测试结果显示,在最大手动力量测试时,两侧差异为1.91±2.1 mm。
股骨压配固定是骨-髌腱-骨移植物的一种替代固定方法,为前交叉韧带重建提供了良好的稳定性。压配固定技术的使用避免了股骨侧大多数界面螺钉或其他硬件引起的并发症。