Abstract

Desorption electrospray ionization (DESI) allows mass spectrometry to be used for on-line high-throughput monitoring of pharmaceutical samples in the ambient environment, without prior sample preparation. Positive and negative ion DESI are used to characterize the active ingredients in pharmaceutical samples formulated as tablets, ointments, and liquids. Compounds of a wide variety of chemical types are detected in these complex matrices. The effects on analytical performance of operating parameters, including the electrospray high voltage, heated capillary temperature, solvent infusion rate, and solvent composition, are evaluated and optimized. In addition to experiments in which a simple solvent is sprayed onto the solid analyte samples, reactive desorption is performed by adding reagents to the solvent spray to generate particularly stable or characteristic ions with the analytes of interest. A variable-speed moving belt was built for high-throughput sampling and used to provide rapid qualitative and semiquantitative information on drug constituents in tablets. Sampling rates as high as 3 samples/s are achieved in the ambient environment. Relative standard deviations of the relative ion abundances for major components in the mass spectra are in the range of 2-8%. Impurities and components present at levels as low as approximately 0.1% are identified and carryover effects are minimized in high-throughput on-line analysis of pharmaceutical samples.

摘要

解吸电喷雾电离(DESI)可使质谱用于在环境中对药物样品进行在线高通量监测,而无需事先进行样品制备。正离子和负离子DESI用于表征制成片剂、软膏和液体的药物样品中的活性成分。在这些复杂基质中可检测到多种化学类型的化合物。对包括电喷雾高压、加热毛细管温度、溶剂注入速率和溶剂组成在内的操作参数对分析性能的影响进行了评估和优化。除了将简单溶剂喷到固体分析物样品上的实验外,还通过向溶剂喷雾中添加试剂来进行反应性解吸,以与目标分析物生成特别稳定或具有特征性的离子。构建了一个变速移动带用于高通量采样,并用于提供片剂中药物成分的快速定性和半定量信息。在环境中实现了高达3个样品/秒的采样率。质谱中主要成分的相对离子丰度的相对标准偏差在2-8%范围内。可识别低至约0.1%水平的杂质和成分,并且在药物样品的高通量在线分析中使残留效应最小化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验