Suppr超能文献

一种用于实时XMR引导的心血管介入系统。

A system for real-time XMR guided cardiovascular intervention.

作者信息

Rhode Kawal S, Sermesant Maxime, Brogan David, Hegde Sanjeet, Hipwell John, Lambiase Pier, Rosenthal Eric, Bucknall Clifford, Qureshi Shakeel A, Gill Jaswinder S, Razavi Reza, Hill Derek L G

机构信息

Division of Imaging Sciences, Guy's, King's & St. Thomas' School of Medicine, King's College London, Guy's Hospital, London SEI 9RT, UK.

出版信息

IEEE Trans Med Imaging. 2005 Nov;24(11):1428-40. doi: 10.1109/TMI.2005.856731.

Abstract

The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sliding table XMR configuration. The aim of our recent work was to extend our technique by providing an improved calibration stage, real-time guidance during cardiovascular catheterization procedures, and further off-line analysis for mapping cardiac electrical data to patient anatomy. Specially designed optical trackers and a dedicated calibration object have resulted in a single calibration step that can be efficiently checked and updated before each procedure. An X-ray distortion model has been implemented that allows for distortion correction for arbitrary c-arm orientations. During procedures, the guidance system provides a real-time combined MR/X-ray image display consisting of live X-ray images with registered recently acquired MR derived anatomy. It is also possible to reconstruct the location of catheters seen during X-ray imaging in the MR derived patient anatomy. We have applied our registration technique to 13 cardiovascular catheterization procedures. Our system has been used for the real-time guidance of ten radiofrequency ablations and one aortic stent implantation. We demonstrate the real-time guidance using two exemplar cases. In a further two cases we show how off-line analysis of registered image data, acquired during electrophysiology study procedures, has been used to map cardiac electrical measurements to patient anatomy for two different types of mapping catheters. The cardiologists that have used the guidance system suggest that real-time XMR guidance could have substantial value in difficult interventional and electrophysiological procedures, potentially reducing procedure time and delivered radiation dose. Also, the ability to map measured electrical data to patient specific anatomy provides improved visualization and a path to investigation of cardiac electromechanical models.

摘要

混合磁共振(MR)/X射线套件(XMR)是一种最近推出的成像解决方案,为心血管导管插入术的引导提供了新的可能性。我们之前已经描述并验证了一种基于光学跟踪的技术,用于配准从滑动台XMR配置中获得的MR和X射线图像。我们近期工作的目的是扩展我们的技术,提供改进的校准阶段、心血管导管插入术期间的实时引导,以及进一步的离线分析,以便将心脏电数据映射到患者解剖结构。专门设计的光学跟踪器和专用校准对象实现了单个校准步骤,该步骤可在每次手术前进行有效检查和更新。已实施X射线畸变模型,可对任意C形臂方向进行畸变校正。在手术过程中,引导系统提供实时组合的MR/X射线图像显示,由带有已配准的最近获取的MR衍生解剖结构的实时X射线图像组成。还可以在MR衍生的患者解剖结构中重建X射线成像期间看到的导管位置。我们已将配准技术应用于13例心血管导管插入术。我们的系统已用于10例射频消融和1例主动脉支架植入的实时引导。我们使用两个示例病例展示了实时引导。在另外两个病例中,我们展示了如何对电生理研究手术期间获取的配准图像数据进行离线分析,以将两种不同类型的标测导管的心脏电测量结果映射到患者解剖结构。使用该引导系统的心脏病专家表示,实时XMR引导在困难的介入和电生理手术中可能具有重大价值,有可能减少手术时间和所接受的辐射剂量。此外,将测量的电数据映射到患者特定解剖结构的能力提供了更好的可视化效果,并为研究心脏机电模型提供了途径。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验