使用ISO 11137方法2B验证用于同种异体移植物灭菌的低剂量伽马辐照工艺。

Validating a low dose gamma irradiation process for sterilizing allografts using ISO 11137 method 2B.

作者信息

Baker Thomas F, Ronholdt Chad J, Bogdansky Simon

机构信息

AlloSource, 6278, S. Troy Circle, Centennial, CO 80111, USA.

出版信息

Cell Tissue Bank. 2005;6(4):271-5. doi: 10.1007/s10561-005-7364-6.

Abstract

This paper describes the validation of an allograft sterilization method specifically designed for the processing methods used at AlloSource in Centennial, CO. The methods used for this validation followed ISO Standard 11137, Method 2B. Three hundred allografts, collected from three defined production batches were dosed using a series of five incremental doses, beginning at 1 kGy and increasing by 1 kGy until 5 kGy was achieved. Following sterilization dosing, each allograft test article was analyzed using a sterility test to identify any viable microorganisms. The number of positive sterility samples was used to calculate the verification dose (1.27 kGy), which was then verified by an additional batch of 100 allografts. The results from this validation indicate that sterility (10(-6) SAL) on human allograft tissue using gamma 60Co radiation can be achieved when a dose of at least 9.2 kGy is employed.

摘要

本文描述了一种同种异体移植灭菌方法的验证过程,该方法是专门为科罗拉多州森特尼尔市的AlloSource所采用的处理方法而设计的。用于此验证的方法遵循ISO标准11137,方法2B。从三个确定的生产批次中收集了300个同种异体移植物,使用一系列五个递增剂量进行辐照,从1 kGy开始,每次增加1 kGy,直至达到5 kGy。灭菌辐照后,对每个同种异体移植测试物品进行无菌测试,以识别任何存活的微生物。阳性无菌样本的数量用于计算验证剂量(1.27 kGy),然后通过另外一批100个同种异体移植物进行验证。该验证结果表明,当采用至少9.2 kGy的剂量时,使用60Co伽马射线对人同种异体移植组织进行辐照可实现无菌状态(10^(-6) 无菌保证水平)。