Suppr超能文献

麻醉的Wistar大鼠的非接触式磁心动图测绘:心脏电活动年龄相关变化的证据

Contactless magnetocardiographic mapping in anesthetized Wistar rats: evidence of age-related changes of cardiac electrical activity.

作者信息

Brisinda Donatella, Caristo Maria Emiliana, Fenici Riccardo

机构信息

Biomagnetism Center, Clinical Physiology, Catholic University of the Sacred Heart, Rome, Italy.

出版信息

Am J Physiol Heart Circ Physiol. 2006 Jul;291(1):H368-78. doi: 10.1152/ajpheart.01048.2005. Epub 2005 Dec 22.

Abstract

Magnetocardiography (MCG) is the recording of the magnetic field (MF) generated by cardiac electrophysiological activity. Because it is a contactless method, MCG is ideal for noninvasive cardiac mapping of small experimental animals. The aim of this study was to assess age-related changes of cardiac intervals and ventricular repolarization (VR) maps in intact rats by means of MCG mapping. Twenty-four adult Wistar rats (12 male and 12 female) were studied, under anesthesia, with the same unshielded 36-channel MCG instrumentation used for clinical recordings. Two sets of measurements were obtained from each animal: 1) at 5 mo of age (297.5 +/- 21 g body wt) and 2) at 14 mo of age (516.8 +/- 180 g body wt). RR and PR intervals, QRS segment, and QTpeak, QTend, JTpeak, JTend, and Tpeak-end were measured from MCG waveforms. MCG imaging was automatically obtained as MF maps and as inverse localization of cardiac sources with equivalent current dipole and effective magnetic dipole models. After 300 s of continuous recording were averaged, the signal-to-noise ratio was adequate for study of atrial and ventricular MF maps and for three-dimensional localization of the underlying cardiac sources. Clear-cut age-related differences in VR duration were demonstrated by significantly longer QTend, JTend, and Tpeak-end in older Wistar rats. Reproducible multisite noninvasive cardiac mapping of anesthetized rats is simpler with MCG methodology than with ECG recording. In addition, MCG mapping provides new information based on quantitative analysis of MF and equivalent sources. In this study, statistically significant age-dependent variations in VR intervals were found.

摘要

磁心动图(MCG)是对心脏电生理活动产生的磁场(MF)进行记录。由于它是一种非接触式方法,MCG对于小型实验动物的无创心脏标测来说是理想的。本研究的目的是通过MCG标测评估完整大鼠心脏间期和心室复极(VR)图的年龄相关变化。对24只成年Wistar大鼠(12只雄性和12只雌性)在麻醉状态下进行研究,使用的是与临床记录相同的非屏蔽36通道MCG仪器。从每只动物获取两组测量值:1)5月龄时(体重297.5±21克)和2)14月龄时(体重516.8±180克)。从MCG波形测量RR和PR间期、QRS段以及QTpeak、QTend、JTpeak、JTend和Tpeak-end。MCG成像通过MF图以及使用等效电流偶极子和有效磁偶极子模型对心脏源进行反向定位自动获得。在对300秒的连续记录进行平均后,信噪比足以用于研究心房和心室MF图以及对潜在心脏源进行三维定位。在老年Wistar大鼠中,QTend、JTend和Tpeak-end显著延长,这表明VR持续时间存在明显的年龄相关差异。与心电图记录相比,使用MCG方法对麻醉大鼠进行可重复的多部位无创心脏标测更简单。此外,MCG标测基于对MF和等效源的定量分析提供了新信息。在本研究中,发现VR间期存在统计学上显著的年龄依赖性变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验