Sirveaux F, Beyaert C, Paysant J, Molé D, André J M
Clinique de Traumatologie et d'Orthopédie, Sincal, Nancy, France.
Clin Orthop Relat Res. 2006 Jan;442:204-9. doi: 10.1097/01.blo.0000180892.10666.43.
Degenerative osteoarthritis in subtalar and midtarsal joints occurring after tibiotalar arthrodesis may be related to biomechanical factors. For patients with tibiotalar arthrodesis walking with their everyday shoes, the ground reaction force is posterior at heel-off and the maximal foot-tibia dorsiflexion is at its upper limit. We hypothesized that increasing the instep of the shoes would improve these abnormalities. Three-dimensional gait analysis was done in nine patients with ankle arthrodesis fused in the neutral position and for 10 control subjects. Four conditions of walking were tested: barefoot, wearing everyday shoes, wearing everyday shoes with the instep increased by 1 cm, and wearing everyday shoes with the instep increased by 2 cm. In the arthrodesis group, the two modified delayed heel-off shoe conditions shifted the ground reaction force closer to the metatarsal heads at heel-off to a normal range, and reduced the maximal foot and tibia dorsiflexion angle. Based on these results, patients with a tibiotalar arthrodesis in the neutral sagittal position may be advised to choose shoes with an instep of approximately 25 mm.
胫距关节融合术后出现的距下关节和中跗关节退行性骨关节炎可能与生物力学因素有关。对于穿着日常鞋子行走的胫距关节融合术患者,足跟离地时地面反作用力位于后方,且足-胫骨最大背屈处于上限。我们推测增加鞋的脚背高度会改善这些异常情况。对9例踝关节融合于中立位的患者和10名对照受试者进行了三维步态分析。测试了四种行走条件:赤脚、穿日常鞋子、穿脚背高度增加1厘米的日常鞋子以及穿脚背高度增加2厘米的日常鞋子。在融合术组中,两种改良的延迟足跟离地的鞋子条件使足跟离地时地面反作用力更接近跖骨头,使其处于正常范围,并减小了足和胫骨最大背屈角度。基于这些结果,对于矢状面处于中立位的胫距关节融合术患者,建议选择脚背高度约为25毫米的鞋子。