This paper presents a study of the stress field forming of sector array transducers for vibro-acoustography applications. The system point-spread function (PSF) is given in terms of the dynamic radiation stress exerted on a point target by a dual ultrasound beam with slightly different frequencies. The radiation stress is calculated by assuming that the resulting ultrasound beam is a plane wave. The stress is proportional to the product of the velocity potential of each incident ultrasound beam. The beamforming and stress field forming of sector array transducers are analyzed through linear acoustics. An expression for the velocity potential produced by sector array transducers is derived. The vibro-acoustography PSF is evaluated numerically. A comparison between the PSF of a sector array and a confocal transducers is presented. The compared characteristics of the PSF are sidelobe levels, transverse, and in-depth spatial resolution. Indeed, one motivation to study sector transducers is the fact the depth-of-field of these transducers should be smaller than that of same size confocal transducers. An experimental setup was used to validate the theoretical PSF of sector array transducers. Results show that the measured PSF is in good agreement with the theoretical predications. Vibro-acoustography images of a breast-phantom by both transducers are presented and discussed.

摘要

本文介绍了一项针对用于振动声成像应用的扇形阵列换能器应力场形成的研究。系统点扩散函数(PSF)是根据频率略有不同的双超声束施加在点目标上的动态辐射应力给出的。通过假设合成超声束为平面波来计算辐射应力。该应力与每个入射超声束的速度势的乘积成正比。通过线性声学分析扇形阵列换能器的波束形成和应力场形成。推导了扇形阵列换能器产生的速度势的表达式。对振动声成像PSF进行了数值评估。给出了扇形阵列和共焦换能器PSF的比较。PSF的比较特性包括旁瓣电平、横向和深度空间分辨率。事实上,研究扇形换能器的一个动机是,这些换能器的景深应小于相同尺寸共焦换能器的景深。使用实验装置来验证扇形阵列换能器的理论PSF。结果表明,测量得到的PSF与理论预测结果吻合良好。展示并讨论了两种换能器对乳腺模型的振动声成像图像。

相似文献

1
Stress field forming of sector array transducers for vibro-acoustography.
IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Nov;52(11):1943-51. doi: 10.1109/tuffc.2005.1561663.
2
Image formation in vibro-acoustography with depth-of-field effects.
Comput Med Imaging Graph. 2006 Jul;30(5):321-7. doi: 10.1016/j.compmedimag.2006.08.001. Epub 2006 Sep 1.
3
Multifrequency vibro-acoustography.
IEEE Trans Med Imaging. 2006 Oct;25(10):1284-95. doi: 10.1109/tmi.2006.882142.
4
Comparison of stress field forming methods for vibro-acoustography.
IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Mar;51(3):313-21.
5
Linear arrays for vibro-acoustography: a numerical simulation study.
Ultrason Imaging. 2004 Jan;26(1):1-17. doi: 10.1177/016173460402600101.
6
Critical issues in breast imaging by vibro-acoustography.
Ultrasonics. 2006 Dec 22;44 Suppl 1:e217-20. doi: 10.1016/j.ultras.2006.06.021. Epub 2006 Jun 30.
7
Implementation of vibro-acoustography on a clinical ultrasound system.
IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Jun;58(6):1169-81. doi: 10.1109/TUFFC.2011.1927.
8
Deconvolution of vibroacoustic images using a simulation model based on a three dimensional point spread function.
Ultrasonics. 2013 Jan;53(1):36-44. doi: 10.1016/j.ultras.2012.03.011. Epub 2012 Apr 21.
9
Preliminary in vivo breast vibro-acoustography results with a quasi-2-d array transducer: a step forward.
Ultrasound Med Biol. 2014 Dec;40(12):2819-29. doi: 10.1016/j.ultrasmedbio.2014.07.005.
10
Imaging mass lesions by vibro-acoustography: modeling and experiments.
IEEE Trans Med Imaging. 2004 Sep;23(9):1087-93. doi: 10.1109/TMI.2004.828674.

引用本文的文献

2
Production of acoustic radiation force using ultrasound: methods and applications.
Expert Rev Med Devices. 2018 Nov;15(11):819-834. doi: 10.1080/17434440.2018.1538782. Epub 2018 Oct 31.
3
Diagnosis of small partial-thickness rotator cuff tears using vibro-acoustography.
J Med Ultrason (2001). 2015 Jan;42(1):3-7. doi: 10.1007/s10396-014-0553-9. Epub 2014 Jun 26.
4
Preliminary in vivo breast vibro-acoustography results with a quasi-2-d array transducer: a step forward.
Ultrasound Med Biol. 2014 Dec;40(12):2819-29. doi: 10.1016/j.ultrasmedbio.2014.07.005.
5
Complex background suppression for vibro-acoustography images.
Ultrasonics. 2015 Feb;56:456-72. doi: 10.1016/j.ultras.2014.09.014. Epub 2014 Sep 30.
7
A beamforming study for implementation of vibro-acoustography with a 1.75-D array transducer.
IEEE Trans Ultrason Ferroelectr Freq Control. 2013 Mar;60(3):535-51. doi: 10.1109/TUFFC.2013.2595.
8
A Review of Vibro-acoustography and its Applications in Medicine.
Curr Med Imaging Rev. 2011 Nov 1;7(4):350-359. doi: 10.2174/157340511798038648.
9
Implementation of vibro-acoustography on a clinical ultrasound system.
IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Jun;58(6):1169-81. doi: 10.1109/TUFFC.2011.1927.
10
Medical ultrasound: imaging of soft tissue strain and elasticity.
J R Soc Interface. 2011 Nov 7;8(64):1521-49. doi: 10.1098/rsif.2011.0054. Epub 2011 Jun 16.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验