Abstract

The sorption conditions including pH of the aqueous solution, sample volume, etc., on Celtek clay of copper(II), cadmium(II), lead(II), chromium(III), nickel(II) and cobalt(II) ions from environmental samples has been studied. The effects of electrolytes as matrix on the preconcentration were also investigated with the recoveries >95%. The 3 sigma detection limits for copper, cadmium, lead, chromium, nickel and cobalt ions were found to be 0.25, 0.32, 0.73, 0.45, 0.50 and 0.41 microg/l, respectively. The relative standard deviation was <10% for the determination of analytes. The procedure was validated by analysis of a NRCC-SLRS 4 Riverine Water, SRM 1573a Tomato leaves and IAEA 336 Lichen standard reference materials. The developed method was successively utilized for the determination of Cu(II), Cd(II), Pb(II), Cr(III), Ni(II) and Co(II) in various samples including natural waters, wheat and human hair by flame atomic absorption spectrometry (FAAS) with satisfactorily results (recoveries>95% and R.S.D.'s<10%).

摘要

研究了从环境样品中吸附铜(II)、镉(II)、铅(II)、铬(III)、镍(II)和钴(II)离子到Celtek粘土上的吸附条件,包括水溶液的pH值、样品体积等。还研究了作为基质的电解质对预富集的影响,回收率>95%。发现铜、镉、铅、铬、镍和钴离子的3σ检测限分别为0.25、0.32、0.73、0.45、0.50和0.41μg/L。分析物测定的相对标准偏差<10%。通过分析NRCC-SLRS 4河流水、SRM 1573a番茄叶和IAEA 336地衣标准参考物质对该方法进行了验证。所建立的方法通过火焰原子吸收光谱法(FAAS)相继用于测定各种样品中的铜(II)、镉(II)、铅(II)、铬(III)、镍(II)和钴(II),包括天然水、小麦和人发,结果令人满意(回收率>95%,相对标准偏差<10%)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验