Current status of patient radiation doses from computed tomography examinations in Tanzania.

作者信息

Ngaile J E, Msaki P, Kazema R

机构信息

Department of Physics, University of Dar es Salaam, P.O. Box 35063, Dar es Salaam, Tanzania.

出版信息

Radiat Prot Dosimetry. 2006;121(2):128-35. doi: 10.1093/rpd/ncl001. Epub 2006 Feb 3.

Abstract

The aim of this study was to assess the magnitude of radiation dose imparted to patients undergoing CT (computed tomography) examinations in Tanzania. The effective doses to patients undergoing five common CT examinations were obtained from eight health centres. The doses to patients were estimated using measurements of CTDI, exposure-related parameters and the CTDOSE software based on NRPB conversion factors. The mean effective doses in Tanzania for CT examinations of head, lumbar spine, chest, abdomen and pelvis were 2.2+/-0.9, 5.4+/-2.3, 12.2+/-3.4, 15.3+/-6.0 and 13.4+/-7.3 mSv, respectively. The mean effective doses and the variations in dose between hospitals in Tanzania were mostly comparable with reported values in the literature for six different countries from Europe. The observed wide variation in mean effective dose for similar CT examination among hospitals was largely influenced by different CT scanning protocols employed among hospitals. In view of the observed causes of variation in patient doses, it was concluded that further studies are needed to investigate the methods that can reduce dose to patients without affecting image quality.

摘要

本研究的目的是评估坦桑尼亚接受CT(计算机断层扫描)检查的患者所接受的辐射剂量大小。从八个健康中心获取了接受五项常见CT检查患者的有效剂量。基于NRPB转换因子,利用CTDI测量值、与曝光相关的参数以及CTDOSE软件来估算患者所接受的剂量。坦桑尼亚头部、腰椎、胸部、腹部和骨盆CT检查的平均有效剂量分别为2.2±0.9、5.4±2.3、12.2±3.4、15.3±6.0和13.4±7.3 mSv。坦桑尼亚各医院之间的平均有效剂量以及剂量变化大多与欧洲六个不同国家文献报道的值相当。医院间相似CT检查的平均有效剂量存在较大差异,这在很大程度上受到各医院采用的不同CT扫描方案的影响。鉴于观察到的患者剂量变化原因,得出的结论是需要进一步研究,以探究在不影响图像质量的情况下降低患者剂量的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验