Suppr超能文献

使用实时区域相位对比磁共振成像评估动脉血流和血管面积变化。

Assessing arterial blood flow and vessel area variations using real-time zonal phase-contrast MRI.

作者信息

Oelhafen Markus, Schwitter Juerg, Kozerke Sebastian, Luechinger Roger, Boesiger Peter

机构信息

Institute for Biomedical Engineering, University of Zurich and Swiss Federal Institute of Technology Zurich, Gloriastrasse 35, CH-8092 Zurich, Switzerland.

出版信息

J Magn Reson Imaging. 2006 Mar;23(3):422-9. doi: 10.1002/jmri.20521.

Abstract

PURPOSE

To measure peripheral artery function using a real-time phase-contrast (PC)-MRI sequence with tailored image-processing algorithms for flow computation.

MATERIALS AND METHODS

An approach to real-time flow measurements was developed based on two-dimensional spatially selective excitation pulses and consecutive tailored processing of the data to derive blood flow and vessel area variations. The data acquisition strategy allows for flow measurements at high spatial and temporal resolutions of 1 mm(2) and 50 msec, respectively. In postprocessing the vessel area is automatically extracted using correlation measures in conjunction with morphological image operators. By means of in vitro and in vivo validations, it is shown that the current methods provide accurate and reproducible measurements of flow and vessel area variations.

RESULTS

In vitro the comparison between the lumen area measured with the presented method and the values obtained by caliper gauge measurement showed a difference of 3.4% +/- 3.4% (mean +/- 2 SD). Similarly, the comparison between the stroke volumes determined with the presented method and by stopwatch and bucket measurements yielded a difference of 6.1% +/- 2.1%. In vivo the results from the real-time measurements for lumen area and stroke volume were compared with those from a gated PC-MRI technique with differences of 4.8% +/- 14% and 3.0% +/- 24.7%, respectively.

CONCLUSION

The presented method constitutes a reliable tool set for quantifying the variations of blood flow and lumen area in the superficial femoral artery during reactive hyperemia and for studying their correlation with cardiovascular risk factors.

摘要

目的

使用实时相位对比(PC)-MRI序列及定制的图像处理算法来计算血流,以测量外周动脉功能。

材料与方法

基于二维空间选择性激发脉冲及对数据进行连续定制处理以得出血流和血管面积变化,开发了一种实时血流测量方法。该数据采集策略允许分别在1 mm²和50毫秒的高空间和时间分辨率下进行血流测量。在后期处理中,结合形态学图像算子,使用相关测量自动提取血管面积。通过体外和体内验证表明,当前方法可提供准确且可重复的血流和血管面积变化测量结果。

结果

在体外,用本方法测量的管腔面积与用卡尺测量所得值之间的比较显示差异为3.4%±3.4%(均值±2标准差)。同样,用本方法测定的每搏量与用秒表和桶测量法所得结果之间的比较产生的差异为6.1%±2.1%。在体内,将实时测量的管腔面积和每搏量结果与门控PC-MRI技术的结果进行比较,差异分别为4.8%±14%和3.0%±24.7%。

结论

本方法构成了一套可靠的工具集,用于量化反应性充血期间股浅动脉血流和管腔面积的变化,并研究它们与心血管危险因素的相关性。