Abstract

Rupture of an iliac artery during percutaneous transluminal coronary angioplasty is a rare but potentially devastating complication. We report a case of iatrogenic external iliac artery rupture that was successfully treated by temporary balloon occlusion followed by endovascular stent graft placement in an unusual manner. Limited availability of the hardware necessitated the use of a longer bare stent graft mounted on a relatively shorter balloon.