Heise M, Schmidmaier G, Husmann I, Heidenhain C, Schmidt J, Neuhaus P, Settmacher U
Department of General Surgery, Charité, University Medicine, Augustenburger Platz 1, D-13353 Berlin, Germany.
Eur J Vasc Endovasc Surg. 2006 Oct;32(4):418-24. doi: 10.1016/j.ejvs.2006.03.002. Epub 2006 May 6.
Small diameter PTFE grafts are prone to thrombosis and intimal hyperplasia development. Heparin graft coating has beneficial effects but also potential drawbacks. The purpose of this study was to evaluate the experimental efficacy of PEG-hirudin/iloprost coated small caliber PTFE grafts.
Thirty-six femoro-popliteal ePTFE grafts (expanded polytetrafluoroethylene, diameter 4 mm) were inserted into 18 pigs. Grafts were randomised individually for each leg and grouped for 3 groups. Group I consisted of native ePTFE grafts, group II were grafts coated with a polylactide polymer (PLA) without drugs and group III grafts were coated with PLA containing a polyethylene glycol (PEG)-hirudin/iloprost combination. The follow-up period was 6 weeks. Patency rates were calculated and development of pseudointima inside the grafts was noted. Thickness of intimal hyperplasia at the distal anastomoses was measured using light microscopy.
Patency rates for group I were 6/9 (67%), for group II 9/10 (90%) and 12/12 (100%) for group III. In groups I and II there was a significant reduction of blood flow proximal to the graft at graft harvest, to 29+/-12 and 28+/-20 ml/min respectively (both p<0.01 versus preoperative value), whilst in group III blood flow, 99+/-21 ml/min, remained at the preoperative level. Subtotal stenosis due to development of pseudointima was noted in each of the native and PLA coated grafts but not in group III grafts. Intimal hyperplasia at the distal anastomosis was lowest in group III.
The PEG-hirudin/iloprost coating of ePTFE prostheses effectively reduced pseudointima and intimal hyperplasia development and led to superior graft patency.
小口径聚四氟乙烯(PTFE)移植物易于发生血栓形成和内膜增生。肝素涂层移植物有有益作用,但也有潜在缺点。本研究的目的是评估聚乙二醇化水蛭素/伊洛前列素涂层小口径PTFE移植物的实验效果。
将36个股腘动脉ePTFE移植物(膨体聚四氟乙烯,直径4mm)植入18头猪体内。每个肢体的移植物单独随机分组,分为3组。第一组为天然ePTFE移植物,第二组为涂有不含药物的聚乳酸聚合物(PLA)的移植物,第三组移植物涂有含聚乙二醇(PEG)-水蛭素/伊洛前列素组合的PLA。随访期为6周。计算通畅率,并记录移植物内假内膜的形成情况。使用光学显微镜测量远端吻合口处内膜增生的厚度。
第一组的通畅率为6/9(67%),第二组为9/10(90%),第三组为12/12(100%)。在第一组和第二组中,移植物取出时移植物近端的血流显著减少,分别降至29±12和28±20ml/min(两者与术前值相比均p<0.01),而第三组的血流为99±21ml/min,保持在术前水平。在天然和PLA涂层移植物中均观察到由于假内膜形成导致的次全狭窄,但在第三组移植物中未观察到。第三组远端吻合口处的内膜增生最低。
ePTFE假体的PEG-水蛭素/伊洛前列素涂层有效减少了假内膜和内膜增生的形成,并导致了更高的移植物通畅率。