McKillop Derek J, Cairns Brian, Duly Ellie, Van Drimmelen Marie, Ryan Michael
Department of Clinical Biochemistry, Belfast Link Laboratories, Belfast, UK.
Ann Clin Biochem. 2006 May;43(Pt 3):220-2. doi: 10.1258/000456306776865098.
The aim of this study was to measure the variability in estimated glomerular filtration rate (eGFR) calculated by laboratories in Northern Ireland where creatinine assays other than the Beckman CX3 assay used to derive the Modification of Diet in Renal Disease (MDRD) are utilized.
Fifty patient samples were analysed for serum creatinine by kinetic Jaffe assays on the Roche modular P-800 (compensated assay), the Beckman LX20 and the Abbott Aeroset analysers.
The median (interquartile range) eGFR calculated by the abbreviated MDRD equation using the creatinine results obtained by each method were 45.4 (31.7-66.6), 49.2 (35.4-78.1) and 50.0 (35.1-71.2) mL/min/1.73 m2 for Beckman, Roche (compensated) and Abbott assays, respectively. Following mathematical alignment of creatinine methods to the Beckman method the median (interquartile range) eGFR for the Roche and Abbott methods were 44.0 (32.0-67.6) and 45.6 (31.2-64.8) mL/min/1.73 m2, respectively.
The regression equations published in this study can be used to align creatinine methods. However, method-related biases in eGFR of up to 10% are minimal in the context of the magnitude of variance reflected in the 90% confidence intervals.
本研究的目的是测量北爱尔兰各实验室使用除用于推导肾脏病饮食改良(MDRD)公式的贝克曼CX3检测法之外的肌酐检测法计算的估计肾小球滤过率(eGFR)的变异性。
采用罗氏模块化P-800分析仪(补偿检测法)、贝克曼LX20分析仪和雅培Aeroset分析仪上的动力学碱性苦味酸法对50份患者样本进行血清肌酐分析。
使用每种方法获得的肌酐结果,通过简化MDRD公式计算的eGFR中位数(四分位间距),贝克曼检测法为45.4(31.7 - 66.6)mL/min/1.73 m²,罗氏(补偿)检测法为49.2(35.4 - 78.1)mL/min/1.73 m²,雅培检测法为50.0(35.1 - 71.2)mL/min/1.73 m²。将肌酐检测法在数学上校准为贝克曼检测法后,罗氏检测法和雅培检测法的eGFR中位数(四分位间距)分别为44.0(32.0 - 67.6)mL/min/1.73 m²和45.6(31.2 - 64.8)mL/min/1.73 m²。
本研究中发表的回归方程可用于校准肌酐检测法。然而,在90%置信区间所反映的方差幅度背景下,eGFR中与方法相关的偏差高达10%是极小的。