Suppr超能文献

基于Spreeta的生物传感器免疫测定法用于检测牛奶和奶粉中的掺假欺诈行为。

Spreeta-based biosensor immunoassays to detect fraudulent adulteration in milk and milk powder.

作者信息

Haasnoot Willem, Marchesini Gerardo R, Koopal Kees

机构信息

RIKILT-Institute of Food Safety, PO Box 230, 6700 AE Wageningen, The Netherlands.

出版信息

J AOAC Int. 2006 May-Jun;89(3):849-55.

Abstract

Biacore biosensors (Biacore AB, Uppsala, Sweden) have proven to be robust analytical tools for the automated immunochemical detection of different adulterants and contaminants in milk and milk powder. However, the significant cost of the instruments is a disincentive for their wide application in food control laboratories. Therefore, a low-cost alternative optical biosensor (Spreeta, Texas Instruments, Attleboro, MA) was built into an affordable liquid handling system. Using this prototype biosensor, an inhibition immunoassay for bovine K-casein was evaluated for the detection of cow's milk in ewe's and goat's milk and for the detection of bovine rennet whey powder in milk powder. Comparable sensitivities were obtained for both adulterants in the Spreeta-based prototype biosensor and a Biacore 3000 instrument. The limit of detection for cow's milk was 0.17% (v/v) and bovine rennet whey powder could be detected in milk powder above 1% (w/w). The Spreeta sensor was also useful in the control of fraudulent water additions to milk, simply by measuring differences in the bulk response.

摘要

Biacore生物传感器(瑞典乌普萨拉市的Biacore AB公司)已被证明是用于自动免疫化学检测牛奶和奶粉中不同掺假物及污染物的强大分析工具。然而,仪器的高昂成本不利于其在食品检测实验室中的广泛应用。因此,一种低成本的替代光学生物传感器(德州仪器公司的Spreeta,马萨诸塞州阿特尔伯勒市)被整合到一个价格合理的液体处理系统中。使用这种原型生物传感器,对用于检测羊奶和山羊奶中牛奶以及奶粉中牛凝乳酶乳清粉的牛κ-酪蛋白抑制免疫测定法进行了评估。基于Spreeta的原型生物传感器和Biacore 3000仪器对这两种掺假物均获得了相当的灵敏度。牛奶的检测限为0.17%(v/v),奶粉中牛凝乳酶乳清粉含量高于1%(w/w)时即可被检测到。通过简单测量总体响应差异,Spreeta传感器在控制向牛奶中掺假加水方面也很有用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验