Suppr超能文献

健康成年人阑尾的多排螺旋CT检查

Multidetector-row CT of the appendix in healthy adults.

作者信息

Johnson Pamela T, Eng John, Moore Carolyn J, Horton Karen M, Fishman Elliot K

机构信息

Russell H. Morgan Department of Radiology, John Hopkins School of Medicine, 601 N. Caroline Street, Room 3251, Baltimore, MD 21287, USA.

出版信息

Emerg Radiol. 2006 Sep;12(6):248-53. doi: 10.1007/s10140-006-0491-y. Epub 2006 Jul 4.

Abstract

The purpose of this study is to characterize the caliber of the normal appendix and the effect of luminal content on appendiceal diameter in adults using thin section intravenous (IV) contrast enhanced multidetector-row computed tomography (MDCT). A retrospective review was conducted using the MDCT datasets from 82 adults being screened as potential renal donors. The four-channel CT technique included IV contrast and 1-mm collimation. Arterial phase scans were reviewed by two radiologists blinded to surgical history, to evaluate the following parameters related to the appendix: quality of visualization, origin and course relative to the cecum, maximum cross-sectional diameter of the lumen and luminal contents at the point of measurement, appearance of the periappendiceal fat, and presence of any luminal calcification. Medical records were reviewed to determine which subjects had reported a previous appendectomy or to confirm the absence of symptoms in any subjects with findings suspicious for appendicitis. The appendix was visualized in 72 of the 77 subjects who did not report an appendectomy (94%). The mean diameter of the collapsed appendix was 5 mm (range: 3-7 mm) and the air-distended appendix, 7 mm (range: 4-10 mm). Sixteen to 17% of the collapsed appendices measured 7 mm in diameter. Minimal periappendiceal stranding was identified in 2/72 subjects (3%). Chart notes from within 24 h of the MDCT confirmed no signs or symptoms of appendicitis in cases that demonstrated any CT finding suspicious for appendicitis. In this healthy, adult population, the collapsed appendix measured up to 7 mm at MDCT. Air distention of the lumen results in a wider diameter, up to 10 mm.

摘要

本研究的目的是利用薄层静脉注射(IV)对比增强多排螺旋计算机断层扫描(MDCT)来描述成人正常阑尾的管径以及管腔内容物对阑尾直径的影响。我们对82名被筛选为潜在肾供体的成人的MDCT数据集进行了回顾性研究。四通道CT技术包括静脉注射对比剂和1毫米准直。两名对手术史不知情的放射科医生对动脉期扫描图像进行评估,以评价与阑尾相关的以下参数:可视化质量、相对于盲肠的起源和走行、测量点处管腔的最大横截面直径和管腔内容物、阑尾周围脂肪的外观以及管腔内是否存在钙化。查阅病历以确定哪些受试者曾报告过阑尾切除术,或确认任何有阑尾炎可疑表现的受试者是否无症状。在77名未报告阑尾切除术的受试者中,72名(94%)的阑尾可见。塌陷阑尾的平均直径为5毫米(范围:3 - 7毫米),充气阑尾的平均直径为7毫米(范围:4 - 10毫米)。16%至17%的塌陷阑尾直径为7毫米。在72名受试者中有2名(3%)发现阑尾周围有轻微条索状影。MDCT检查后24小时内的病历记录证实,在任何有阑尾炎可疑CT表现的病例中均无阑尾炎的体征或症状。在这个健康的成年人群中,MDCT显示塌陷阑尾的直径最大为7毫米。管腔充气会导致直径增宽,最大可达10毫米。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验