Friedman Lee, Glover Gary H, Krenz Diana, Magnotta Vince
Department of Psychiatry and Human Behavior, University of California-Irvine, CA 92617, USA.
Neuroimage. 2006 Oct 1;32(4):1656-68. doi: 10.1016/j.neuroimage.2006.03.062. Epub 2006 Jul 27.
Scanner-to-scanner variability of activation in multicenter fMRI studies is often considered undesirable. The purpose of this investigation was to evaluate the effect of a new procedure, "smoothness equalization", on reducing scanner differences in activation effect size as part of a multicenter fMRI project (FIRST BIRN). Five subjects were sent to 9 centers (10 scanners) and scanned on 2 consecutive days using a sensorimotor fMRI protocol. High-field (4 T and 3 T) and low-field (1.5 T) scanners from three vendors (GE, Siemens, and Picker) were included. The activation effect size of the scanners for the detection of neural activation during a sensorimotor task was evaluated as the percent of temporal variance accounted for by our model (percent of variance accounted for or PVAF). Marked scanner effects were noted for both PVAF as well as the degree of smoothness of the raw and processed images. After smoothness equalization, there was a dramatic (low field) or consistent (high-field) reduction in scanner-to-scanner variation of activation. It was shown that the likely basis of the scanner differences in smoothness was differences in k-space filtering algorithms. This work highlights the need to account for differences in smoothness when comparing scanners on activation effect size in multicenter fMRI studies.
在多中心功能磁共振成像(fMRI)研究中,扫描仪之间激活情况的变异性通常被认为是不理想的。本研究的目的是评估一种新程序“平滑度均衡”对减少扫描仪在激活效应大小方面差异的效果,这是多中心fMRI项目(FIRST BIRN)的一部分。五名受试者被送往9个中心(10台扫描仪),并使用感觉运动fMRI方案连续两天进行扫描。其中包括来自三个供应商(通用电气、西门子和皮克)的高场(4T和3T)和低场(1.5T)扫描仪。将扫描仪在感觉运动任务期间检测神经激活的激活效应大小评估为我们的模型所解释的时间方差百分比(方差解释百分比或PVAF)。对于PVAF以及原始图像和处理后图像的平滑度程度,均发现了明显的扫描仪效应。经过平滑度均衡后,扫描仪之间激活的变异性出现了显著(低场)或一致(高场)的降低。结果表明,扫描仪在平滑度方面存在差异的可能原因是k空间滤波算法的不同。这项工作突出了在多中心fMRI研究中比较扫描仪在激活效应大小方面时考虑平滑度差异的必要性。