A rapid competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) test strip for microcystin-LR (MCLR) determination.

作者信息

Zhang Fenghua, Yang Soon Hye, Kang Tae Young, Cha Geun Sig, Nam Hakhyun, Meyerhoff Mark E

机构信息

Chemical Sensor Research Group, Department of Chemistry, Kwangwoon University, Seoul 139-701, Republic of Korea.

出版信息

Biosens Bioelectron. 2007 Feb 15;22(7):1419-25. doi: 10.1016/j.bios.2006.06.021. Epub 2006 Aug 2.

Abstract

A competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) is described for the determination of microcystin-LR (MCLR) using a double-sided microporous gold electrode in cartridge-type cells. A gold film sputtered on one side of porous nylon membrane constitutes a working electrode, while another gold film formed on the opposite side serves as a pseudo reference electrode. After immobilizing MCLR antibody on working electrode by physical adsorption, the double-sided electrode was placed simply in a diffusion U-type or within a dry strip-type cell with a conjugate pad pre-loaded with a glucose oxidase labeled MCLR (GOx-MCLR) on working electrode side. Assays were performed in two steps: an MCLR-containing sample mixed with a known amount of GOx-MCLR conjugate either in buffer solution or in pre-loaded dry pad was incubated for an appropriate period (about 10 min) to induce competitive reaction with an immobilized anti-MCLR antibody on working electrode, and a fixed concentration of glucose solution (substrate) was then added to the backside of the working electrode. Due to the competitive nature of the assay, enzymatically generated product, hydrogen peroxide (H2O2), was detected at the working gold electrode (at +800 mV versus Au) by oxidation, and the magnitude of amperometric current was inversely proportional to the concentration of MCLR in the sample. The response time after substrate addition was about 30s. Mean recovery of MCLR added to tap water was 93.5%, with a coefficient of variation (CV) of 6.6%. The proposed competitive NEEIA system is in general comparable to existing heterogeneous enzyme immunoassays with a similar detection limit (100 pg/mL MCLR), and suitable for developing a disposable type biosensor for on-site monitoring of environment.

摘要

相似文献

1
A rapid competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) test strip for microcystin-LR (MCLR) determination.
Biosens Bioelectron. 2007 Feb 15;22(7):1419-25. doi: 10.1016/j.bios.2006.06.021. Epub 2006 Aug 2.
6
Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples.
Environ Sci Technol. 2015 Aug 4;49(15):9256-63. doi: 10.1021/acs.est.5b01674. Epub 2015 Jul 13.
7
Highly sensitive and rapid detection of microcystin-LR in source and finished water samples using cantilever sensors.
Environ Sci Technol. 2011 Feb 15;45(4):1490-6. doi: 10.1021/es1020795. Epub 2010 Dec 28.
8
A membrane-based ELISA assay and electrochemical immunosensor for microcystin-LR in water samples.
Environ Sci Technol. 2012 May 15;46(10):5504-10. doi: 10.1021/es2041042. Epub 2012 Apr 24.
9
An SPR biosensor for the detection of microcystins in drinking water.
Anal Bioanal Chem. 2010 Nov;398(6):2625-34. doi: 10.1007/s00216-010-3856-8. Epub 2010 Jun 9.
10
Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode.
Biosens Bioelectron. 2006 Mar 15;21(9):1719-26. doi: 10.1016/j.bios.2005.08.008. Epub 2005 Sep 28.

引用本文的文献

1
Assembling Amperometric Biosensors for Clinical Diagnostics.
Sensors (Basel). 2008 Feb 27;8(3):1366-1399. doi: 10.3390/s8031366.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验