Pelliccioni Giuseppe, Scarpino Osvaldo
Neurology Unit, Geriatric Hospital, INRCA, Ancona, Italy.
Neurourol Urodyn. 2006;25(7):788-91. doi: 10.1002/nau.20215.
The aim of this study is to present the normative data of direct and reflex motor anal sphincter responses, simultaneously evoked by S3 surface electrical stimulation. By this method, it is possible to test the functional integrity of the nervous pathways activated during sacral neuromodulation (SNM).
Twenty healthy subjects were studied. Motor-evoked potentials (MEPs) were recorded by concentric needle electrode from external anal sphincter (EAS). Electrical stimulation was applied by means of a bipolar surface electrode over the S3 right or left sacral foramina.
Direct (R1) and reflex responses (R2 and R3) were found at latencies of 6.98, 25.12, and 50.31 msec, respectively. The two first responses were recorded in all the cases; the last response is steadily recorded in 17 out of 20 subjects.
Our data can serve as reference values for future study in patients with pelvic floor dysfunction. EAS responses following S3 percutaneous electrical stimulation can represent a useful aid in the selection of candidates to SNM.
本研究旨在呈现由S3表面电刺激同时诱发的直接和反射性肛门括约肌运动反应的标准数据。通过这种方法,可以测试在骶神经调节(SNM)期间激活的神经通路的功能完整性。
对20名健康受试者进行了研究。通过同心针电极从肛门外括约肌(EAS)记录运动诱发电位(MEP)。通过双极表面电极在右侧或左侧S3骶孔上方施加电刺激。
分别在6.98、25.12和50.31毫秒的潜伏期发现直接反应(R1)和反射反应(R2和R3)。所有病例均记录到前两个反应;在20名受试者中,有17名稳定记录到最后一个反应。
我们的数据可作为未来盆底功能障碍患者研究的参考值。S3经皮电刺激后的EAS反应可为SNM候选者的选择提供有用的帮助。