Suppr超能文献

使用西罗莫司洗脱可生物降解聚-L-丙交酯支架进行髂动脉吻合口支架置入术:6周后的初步研究

Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after 6 weeks.

作者信息

Bünger Carsten Michael, Grabow Niels, Kröger Christina, Lorenzen Björn, Hauenstein Karlheinz, Goosmann Martin, Schmitz Klaus-Peter, Kreutzer Hans Jürgen, Lootz Daniel, Ince Hüseyin, Nienaber Christoph A, Klar Ernst, Schareck Wolfgang, Sternberg Katrin

机构信息

Department of Surgery, University of Rostock, Germany.

出版信息

J Endovasc Ther. 2006 Oct;13(5):630-9. doi: 10.1583/06-1899R.1.

Abstract

PURPOSE

To assess technical feasibility and biocompatibility of a new biodegradable sirolimus-eluting poly-L-lactide (PLLA) vascular anastomotic stent.

METHODS

A polytetrafluoroethylene bifurcated graft was implanted in 9 pigs through a midline abdominal incision. After transverse graft limb incision, 6 unloaded PLLAs, 6 sirolimus-loaded PLLAs, and 6 unloaded stainless steel (316L) stents were randomly implanted at both iliac anastomotic sites. Stents were deployed with a 6-mm balloon under direct vision without the use of angiography. Prior to sacrifice after 6 weeks, contrast-enhanced computed tomography (CT) was performed to determine patency of the target vessels. Stented segments were surgically explanted and processed for histology to measure the mean luminal diameter and intimal thickness and to assign vascular injury and inflammation scores.

RESULTS

No animals were lost during the study period. All stented graft limbs were patent on CT and histology. At the anastomotic sites and iliac arteries, the mean luminal diameter of SIR-PLLA stents (4.11+/-0.15 and 4.08+/-0.13 mm, respectively) were comparable to metal stents (4.23+/-0.35 and 4.21+/-0.26 mm, respectively), but significantly higher compared to unloaded PLLA stents [3.32+/-0.56 mm (p<0.001) and 3.29+/-0.39 mm (p=0.013), respectively]. At the iliac arteries, the mean intimal thickness was significantly lower with SIR-PLLA stents (0.09+/-0.02 mm) compared to unloaded PLLA stents (0.31+/-0.15 mm, p<0.001) and metal stents (0.19+/-0.04 mm, p=0.004). Vascular injury scores demonstrated only mild vascular trauma for all stents (SIR-PLLA: 0.42+/-0.63, PLLA: 0.51+/-0.62, metal: 0.50+/-0.62). Only mild inflammatory reaction was noted around SIR-PLLA stent struts (1.14+/-0.46), which was comparable to metal stents (1.27+/-0.45) but significantly lower than PLLA stents (1.79+/-0.56, p<0.001).

CONCLUSION

SIR-PLLA stents showed comparable luminal diameter compared to metal stents, so incorporating sirolimus could reduce the inflammatory and neointimal response to PLLA stents. These findings need to be assessed with longer follow-up to confirm maintenance of efficacy.

摘要

目的

评估一种新型可生物降解的西罗莫司洗脱聚左旋乳酸(PLLA)血管吻合支架的技术可行性和生物相容性。

方法

通过腹部正中切口将聚四氟乙烯分叉移植物植入9头猪体内。在移植物肢体横向切开后,将6个未负载的PLLA、6个负载西罗莫司的PLLA和6个未负载的不锈钢(316L)支架随机植入双侧髂血管吻合部位。在直视下使用6毫米球囊展开支架,不使用血管造影术。在6周后处死动物之前,进行对比增强计算机断层扫描(CT)以确定目标血管的通畅情况。通过手术取出带支架的节段并进行组织学处理,以测量平均管腔直径和内膜厚度,并给出血管损伤和炎症评分。

结果

在研究期间没有动物死亡。所有带支架的移植物肢体在CT和组织学检查中均通畅。在吻合部位和髂动脉处,西罗莫司 - PLLA支架的平均管腔直径(分别为4.11±0.15毫米和4.08±0.13毫米)与金属支架(分别为4.23±0.35毫米和4.21±0.26毫米)相当,但与未负载的PLLA支架相比显著更高[分别为3.32±0.56毫米(p<0.001)和3.29±0.39毫米(p = 0.013)]。在髂动脉处,西罗莫司 - PLLA支架的平均内膜厚度(0.09±0.02毫米)明显低于未负载的PLLA支架(0.31±0.15毫米,p<0.001)和金属支架(0.19±0.04毫米,p = 0.004)。血管损伤评分显示所有支架仅造成轻度血管创伤(西罗莫司 - PLLA:0.42±0.63,PLLA:0.51±0.62,金属:0.50±0.62)。在西罗莫司 - PLLA支架支柱周围仅观察到轻度炎症反应(1.14±0.46),这与金属支架(1.27±0.45)相当,但明显低于PLLA支架(1.79±0.56,p<0.001)。

结论

西罗莫司 - PLLA支架与金属支架相比显示出相当的管腔直径,因此加入西罗莫司可减少对PLLA支架的炎症和新生内膜反应。这些发现需要更长时间的随访评估以确认疗效的维持情况。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验