Hoth S, Benz M
Univisitäts-HNO-Klinik Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Deutschland.
HNO. 2007 Jun;55(6):447-56. doi: 10.1007/s00106-006-1455-y.
Central auditory processing disorders (CAPD) are associated with reduced discriminatory abilities of the auditory system. One of these abilities is directional hearing, which is based on the evaluation of interaural signal differences. Since these differences affect also the binaural difference potentials (BDP), these derived evoked potentials could be suitable for the objective detection of disabilities in acoustic localization.
Auditory brainstem responses (ABR) evoked by monaural and binaural stimulation were recorded in 32 adult normal-hearing volunteers at stimulus levels between 10 and 80 dB nHL and the BDP were derived. Additionally, a test of directional hearing was performed and evaluated.
BDP are detectable at all stimulus levels without difficulties, with acceptable examination times and with satisfactory reliability in a routine clinical environment. The electrodes can be positioned at the mastoid (A1 and A2) and vertex (Cz) as for conventional ABR recording. Normal ranges are given for latency and amplitude as well as for their lateral differences.
The spectrum in directional hearing ability as covered by normal-hearing subjects is not mirrored in the parameters of their BDP. Nevertheless, it cannot be ruled out that a real impairment of directional hearing goes along with significantly altered BDP.
中枢听觉处理障碍(CAPD)与听觉系统辨别能力下降有关。其中一种能力是定向听力,它基于对双耳信号差异的评估。由于这些差异也会影响双耳差异电位(BDP),因此这些诱发电位可能适用于客观检测声学定位方面的障碍。
在32名听力正常的成年志愿者中记录了单耳和双耳刺激诱发的听觉脑干反应(ABR),刺激强度在10至80 dB nHL之间,并得出BDP。此外,进行并评估了定向听力测试。
在常规临床环境中,在所有刺激水平下都能轻松检测到BDP,检查时间可接受,可靠性令人满意。电极可以像常规ABR记录一样置于乳突(A1和A2)和头顶(Cz)。给出了潜伏期、振幅及其侧向差异的正常范围。
听力正常受试者的定向听力能力范围并未反映在其BDP参数中。然而,不能排除定向听力的真正损害会伴随BDP的显著改变。