Chamorro C I, Almenar L, Martínez-Dolz L, Reganon E, Sánchez-Lacuesta E, Villa P, Ten F, Andrés L, Martínez-Sales V, Salvador A
Cardiac Failure and Transplant Unit, La Fe University Hospital, Valencia, Spain.
Transplant Proc. 2006 Oct;38(8):2566-8. doi: 10.1016/j.transproceed.2006.08.026.
Cardiac allograft vasculopathy (CAV) is a disease that significantly limits the survival of transplant patients intravascular ultrasound (IVUS) is considered the method of choice for its diagnosis. von Willebrand factor (vWf) has been used as a marker of endothelial malfunction. We sought to evaluate the usefulness of vWf as a CAV marker.
We prospectively analyzed 22 cardiac transplant subjects, on whom we performed a first study using coronary angiography and IVUS at 36 +/- 3 days and a second study at 598 +/- 49 days. During the follow-up period, five vWf serum controls were performed per patient. We analyzed the results with the repeated-measures ANOVA test and a ROC curve.
CAV was detected in 10 (45.5%) of the 22 patients. Although vWf levels tended to diminish progressively during evolution, this trend was not statistically significant (P = .3). However, differences were appreciated based on the presence versus absence of CAV (298 +/- 139 mg/dL versus 212 +/- 105 mg/dL, P = .02). The ROC curve showed a sensitivity of 40%, a specificity of 83%, and a negative predictive value of 82% with a cutoff point of 300 mg/dL.
Subjects with CAV showed significantly higher vWf serum concentrations, particularly during the preliminary phases of cardiac transplantation decreasing during its evolution. This marker could be useful for early screening of CAV.