Romaniv Natalya, Price Marianne O, Price Francis W, Mamalis Nick
John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA.
Cornea. 2006 Sep;25(8):943-7. doi: 10.1097/01.ico.0000243950.99472.f5.
To describe histopathologic characteristics of an endothelial keratoplasty (EK) that was performed to treat a previously failed penetrating keratoplasty (PK) and in which the cornea failed to clear after partial detachment of Descemet membrane from the EK donor button. The Descemet membrane and endothelium from the PK were intentionally retained during the EK procedure.
After EK, the cornea failed to fully clear in 5 months, and a PK was performed. The removed corneal button was grossly described and routinely processed for hematoxylin-eosin (H&E) and periodic acid-Schiff (PAS) staining, with photographs taken of any pertinent findings.
Grossly on the endothelial side, there was some adherent iris pigment delineating an off-center fold in the EK Descemet membrane, consistent with intraoperative observation of a fold across the width of the donor button and postoperative slit-lamp images showing partial detachment of Descemet membrane. Microscopic examination revealed a recipient corneal button from a prior PK centrally and EK donor button attached posteriorly. Descemet membrane was not stripped from the prior PK during EK and was intact. No endothelial cells were detected on the PK Descemet membrane. The anterior stromal surface of the EK was well apposed to the prior PK Descemet membrane, with no pseudoanterior chamber or cleft of any type noted between them. The EK Descemet membrane had a central fold, and the endothelium was markedly attenuated.
The EK graft was well apposed with apparent good adherence to the recipient's prior failed PK, and early endothelial failure was attributable to partial Descemet membrane detachment.
描述为治疗先前失败的穿透性角膜移植术(PK)而进行的内皮角膜移植术(EK)的组织病理学特征,该例中EK供体植片的Descemet膜部分脱离后角膜仍未清亮。在EK手术过程中,特意保留了PK的Descemet膜和内皮。
EK术后5个月角膜未完全清亮,遂行PK。对切除的角膜植片进行大体描述,并常规进行苏木精-伊红(H&E)和过碘酸希夫(PAS)染色,拍摄任何相关发现的照片。
在内皮侧大体观察,有一些附着的虹膜色素勾勒出EK的Descemet膜偏心褶皱,这与术中观察到的供体植片全宽的褶皱以及术后裂隙灯图像显示的Descemet膜部分脱离一致。显微镜检查显示中央为先前PK的受体角膜植片,后方附着EK供体植片。EK手术期间未从先前的PK上剥离Descemet膜,其完整无损。在PK的Descemet膜上未检测到内皮细胞。EK的前基质表面与先前PK的Descemet膜贴合良好,两者之间未发现任何类型的假前房或裂隙。EK的Descemet膜有中央褶皱,内皮明显变薄。
EK移植物与受体先前失败的PK贴合良好且明显粘连,早期内皮功能衰竭归因于Descemet膜部分脱离。