Suppr超能文献

Dynamic light scattering in ophthalmology: results of in vitro and in vivo experiments.

作者信息

Fankhauser Franz

机构信息

Department of Ophthalmology, Städtisches Klinikum, Auenweg 38, D-06847 Dessau, Germany.

出版信息

Technol Health Care. 2006;14(6):521-35.

Abstract

OBJECTIVE

To calibrate new dynamic light scattering (DLS) devices in defined solutions and post mortem porcine and human eyes. To examine all segments of the eye and to become familiar with the usage of the technique in living subjects. METHODS, DESIGN: Three new DLS devices for the usage in patients were developed. Mono-disperse solutions, poly-disperse solutions, gels, post mortem porcine and human eyes as well as healthy volunteers were studied. The detected signals were inverted into autocorrelation functions.

RESULTS

We constructed three DLS devices appropriate for in vitro as well as in vivo examinations. In mono disperse solution precise disintegration rates could be calculated. In poly-disperse solutions, in gel and in the vitreous the results did not correlate with movements of individual particles but we could calculate characteristics of the complete scattering system. In vivo measurements demonstrated that DLS can be used in all human eye segments.

DISCUSSION

DLS is a unique technique. With DLS the molecular composition of eye segments can be studied in living subjects. This can be used to understand the molecular basis of severe eye diseases. The presented data demonstrate that DLS delivers reproducible data from all eye segments.

CONCLUSIONS

It is possible to study the molecular structures of eye segments in living subjects. The developed devices were proved successfully in vitro as well as in vivo. Limitations are the low specificity of DLS and its sensitivity to background noise. Now clinical studies are necessary to demonstrate potential diagnostic benefits of DLS in specific eye diseases.