使用阻抗心动图测定心输出量时电极放置的新方法。

New method of electrode placement for determination of cardiac output using impedance cardiography.

作者信息

Barde Pradip B, Jindal Ghanshyam D, Singh Rajvir, Deepak Kishore K

机构信息

Department of Physiology, All India Institute of Medical Sciences, New Delhi 110 029.

出版信息

Indian J Physiol Pharmacol. 2006 Jul-Sep;50(3):234-40.

Abstract

In thirty eight young healthy adult subjects, cardiac output was determined non-invasively by using two methods of electrode placement viz. vertical (uses silver braided wires in a band shape) and horizontal (conventional stick-on type surface ECG electrodes), using the technique of Impedance Cardiography. The recordings were taken in supine position on the same day in two separate sets with 30.0 min interval between two sets. In each set of recording, five successive recordings, each at an interval of five minutes were taken. The mean values of cardiac out put by two methods were compared. For the set I, the respective values (Mean +/- SD) of cardiac output by horizontal and vertical methods for the each of the five recordings were 4.87 +/- 0.77 and 5.03 +/- 0.64 for the first, 4.87 +/- 0.71 and 4.91 +/- 0.66 for the second, 4.99 +/- 0.67 and 5.00 +/- 0.70 for the third, 4.78 +/- 0.69 and 4.98 +/- 0.61 for the fourth, 4.84 +/- 0.69 and 4.98 +/- 0.62 for the fifth recording in supine position. The respective P values for these pairs for between the group comparisons were 0.33, 0.50, 0.96, 0.17, and 0.36. In addition, to see the repeatability for each method, within the group comparison was done, the P values were 0.71 and 0.91 for the horizontal and vertical methods, respectively. The mean value of cardiac output did not differ significantly between two methods for recordings of set II in supine position. The cardiac output measurement by placing four spot electrodes horizontally, gave consistent result on repeated measurements and their values showed concordance with the cardiac output values obtained by conventional four band electrodes tied around the chest.

摘要

在38名年轻健康的成年受试者中,采用阻抗心动图技术,通过两种电极放置方法,即垂直放置(使用带状银编织线)和水平放置(传统的粘贴式表面心电图电极),对心输出量进行了无创测定。记录在同一天的仰卧位进行,分两组进行,两组之间间隔30.0分钟。在每组记录中,每隔五分钟进行五次连续记录。比较了两种方法测得的心输出量的平均值。对于第一组记录,仰卧位时五次记录中每次水平和垂直方法测得的心输出量的各自值(平均值±标准差),第一次分别为4.87±0.77和5.03±0.64,第二次为4.87±0.71和4.91±0.66,第三次为4.99±0.67和5.00±0.70,第四次为4.78±0.69和4.98±0.61,第五次为4.84±0.69和4.98±0.62。这些组间比较的成对P值分别为0.33、0.50、0.96、0.17和0.36。此外,为了观察每种方法的重复性,进行了组内比较,水平和垂直方法的P值分别为0.71和0.91。仰卧位第二组记录中,两种方法测得的心输出量平均值无显著差异。水平放置四个点状电极测量心输出量,重复测量结果一致,其值与胸部环绕传统四带电极获得的心输出量值一致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验