Comparison of median and radial sensory studies to the thumb.

作者信息

Berkson Andrew, Lohman James, Buschbacher Ralph M

机构信息

Department of Physical Medicine and Rehabilitation, Indiana University, Indianapolis, IN 46202.

出版信息

J Long Term Eff Med Implants. 2006;16(5):387-94. doi: 10.1615/jlongtermeffmedimplants.v16.i5.80.

Abstract

There are multiple reports of neurological injury from both the implantation and the removal of devices utilized in orthopedics. Nerve conduction studies can be a valuable tool in evaluating the acuity, severity, and prognosis of these injuries, as well as in tracking their course. This study was undertaken in an effort to create a large normative database for examining median and radial sensory nerve conduction studies to the first digit. An antidromic technique was employed utilizing a 10-cm distance between the stimulating and recording electrodes. Two hundred three asymptomatic volunteers were tested. Onset latency, peak latency, onset-to-peak amplitude, peak-to-peak amplitude, area, rise time, and duration of the waveforms were measured. Males, older subjects, and those with higher body mass index (BMI) were found to have lower amplitude and area on the median nerve studies. Age was the only variable which demonstrated significant correlation with differing results on the radial nerve studies. Mean onset latencies were 2.1 +/- 0.2 ms for the median nerve and 2.0 +/- 0.2 ms for the radial nerve. Mean peak latencies were 2.7 +/- 0.2 ms for the median nerve and 2.6 +/- 0.2 ms for the radial nerve. Mean peak-to-peak amplitude for the median nerve was 45 +/- 24 muV and for the radial nerve was 12 +/- 9 muV. The upper limit of normal difference in median-versus-radial onset latency was 0.5 ms (0.6 ms for peak latency). The upper limit of normal difference in radial-minus-median onset latency was 0.3 ms (0.4 ms for peak latency).

摘要

相似文献

1
Comparison of median and radial sensory studies to the thumb.
J Long Term Eff Med Implants. 2006;16(5):387-94. doi: 10.1615/jlongtermeffmedimplants.v16.i5.80.
2
Median and ulnar antidromic sensory studies to the fourth digit.
J Long Term Eff Med Implants. 2006;16(5):377-86. doi: 10.1615/jlongtermeffmedimplants.v16.i5.70.
3
Radial versus dorsal ulnar cutaneous sensory studies.
J Long Term Eff Med Implants. 2006;16(5):349-58. doi: 10.1615/jlongtermeffmedimplants.v16.i5.40.
4
Median and Ulnar 14-cm Antidromic Sensory Studies to the Third and Fifth Digits-A Comparison of Amplitude.
J Long Term Eff Med Implants. 2006;16(5):401-5. doi: 10.1615/jlongtermeffmedimplants.v16.i5.100.
6
Median 14-cm and 7-cm antidromic sensory studies to digits two and three.
Am J Phys Med Rehabil. 1999 Nov-Dec;78(6 Suppl):S53-62. doi: 10.1097/00002060-199911001-00011.
7
Mixed nerve conduction studies of the median and ulnar nerves.
Am J Phys Med Rehabil. 1999 Nov-Dec;78(6 Suppl):S69-74. doi: 10.1097/00002060-199911001-00013.
9
Ulnar 14-cm and 7-cm antidromic sensory studies to the fifth digit: reference values derived from a large population of normal subjects.
Am J Phys Med Rehabil. 1999 Nov-Dec;78(6 Suppl):S63-8. doi: 10.1097/00002060-199911001-00012.
10
Effect of interelectrode distance on sural nerve action potential parameters.
Am J Phys Med Rehabil. 2008 Mar;87(3):183-8. doi: 10.1097/PHM.0b013e318164aa04.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验