da Cunha Marcia Regina Bernardi, Puppin-Rontani Regina Maria, Ferracane Jack L, Correr-Sobrinho Lourenço
Department of Restorative Dentistry, Federal University of Paraíba, Brazil.
Am J Dent. 2006 Dec;19(6):364-9.
To evaluate the effect of dental materials on primary enamel wear.
Four composites (Filtek Z250, Heliomolar, Point 4, SureFil), two compomers (Dyract AP, F2000) and a resin-modified glass-ionomer (Vitremer) were placed into box-shaped preparations in buccal surfaces of primary molars and stored for 24 hours in water at 37 degrees C. The specimens (n = 6) were subjected to abrasive three-body wear against a primary enamel cusp. Material wear, enamel wear (adjacent to the material), and wear on enamel cusps were estimated by profilometry and video-analysis software. Results were compared with ANOVA and Tukey's tests (P < 0.05).
Vitremer showed the highest wear (P < 0.05), followed by Dyract AP and F2000, which were not statistically different (P > 0.05). There was no significant difference between Filtek Z250 and Dyract AP (P > 0.05). Filtek Z250, Heliomolar, Point 4 and SureFil, showed the lowest wear values and there was no difference among them (P > 0.05). The highest wear values on the enamel adjacent to the material were found with Dyract AP (P < 0.05) and the lowest next to Point 4 and SureFil (P < 0.05). There was no difference in the wear of the enamel next to Vitremer, F2000, Heliomolar and Filtek Z250 (P > 0.05). Vitremer and F2000 caused the highest wear on enamel cusps (P < 0.05), and there was no statistically significant difference (P > 0.05) between them; SureFil caused the lowest wear (P < 0.05) on the opposing enamel. There was a correlation (r = 0.85) between wear of materials and wear on the enamel cusps, but not (r = 0.53) for the wear on enamel besides the restoration and wear on enamel cusps. SEM micrographs showed different surface characteristics of the materials after the wear test.
评估牙科材料对乳牙釉质磨损的影响。
将四种复合树脂(Filtek Z250、Heliomolar、Point 4、SureFil)、两种聚酸改性复合树脂(Dyract AP、F2000)和一种树脂改性玻璃离子水门汀(Vitremer)放置于乳磨牙颊面的盒状预备洞中,并在37℃的水中储存24小时。对标本(n = 6)针对乳牙釉质尖进行三体磨耗试验。通过轮廓仪和视频分析软件评估材料磨损、(材料相邻处的)釉质磨损以及釉质尖的磨损情况。结果采用方差分析和Tukey检验进行比较(P < 0.05)。
Vitremer显示出最高的磨损(P < 0.05),其次是Dyract AP和F2000,二者无统计学差异(P > 0.05)。Filtek Z250和Dyract AP之间无显著差异(P > 0.05)。Filtek Z250、Heliomolar、Point 4和SureFil显示出最低的磨损值,它们之间无差异(P > 0.05)。材料相邻处釉质的最高磨损值出现在Dyract AP组(P < 0.05),最低值出现在Point 4和SureFil组旁边(P < 0.05)。Vitremer、F2000、Heliomolar和Filtek Z250相邻处釉质的磨损无差异(P > 0.05)。Vitremer和F2000导致釉质尖的磨损最高(P < 0.05),二者之间无统计学显著差异(P > 0.05);SureFil导致相对釉质的磨损最低(P < 0.05)。材料磨损与釉质尖磨损之间存在相关性(r = 0.85),但修复体旁釉质磨损与釉质尖磨损之间不存在相关性(r = 0.53)。扫描电子显微镜照片显示了磨损试验后材料不同的表面特征。