A novel dimethyl sulfoxide (DMSO) sensor using DMSO reductase and film electrodes was constructed. The Au and Ag electrodes were fabricated on slide glass by vacuum deposition and the application of a photolithographic technique. The micro-chamber (4 x 50 x 1 mm, volume 200 microl) was fabricated on a poly(dimethylsiloxane) (PDMS) polymer. The Pt electrode was implanted in a PDMS polymer. DMSO reductase was immobilized on a Au film electrode with bovine serum albumin (BSA)-glutaraldehyde. This sensor could determine DMSO in an unpurged aqueous solution with glucose oxidase (GOD) and catalase (CAT) for oxygen removal. The DMSO sensor showed a linear response within 1 mM DMSO with a correlation coefficient of 0.999. The detection limit was 200 microM (3sigma), and the sensitivity was 23.8 mA M(-1) cm(-2). The relative standard deviations at each concentration were within 3.6%.

摘要

构建了一种使用二甲基亚砜还原酶和薄膜电极的新型二甲基亚砜(DMSO)传感器。通过真空沉积和光刻技术在载玻片上制备金电极和银电极。在聚二甲基硅氧烷(PDMS)聚合物上制备微腔(4×50×1mm,体积200微升)。将铂电极植入PDMS聚合物中。用牛血清白蛋白(BSA)-戊二醛将二甲基亚砜还原酶固定在金膜电极上。该传感器可以在未净化的水溶液中,利用葡萄糖氧化酶(GOD)和过氧化氢酶(CAT)去除氧气来测定二甲基亚砜。该二甲基亚砜传感器在1mM二甲基亚砜范围内呈现线性响应,相关系数为0.999。检测限为200μM(3σ),灵敏度为23.8 mA M(-1) cm(-2)。各浓度下的相对标准偏差在3.6%以内。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验