Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

作者信息

Katoh Marcus, Kühl Harald P, Spuentrup Elmar, Lipke Claudia S A, Günther Rolf W, Buecker Arno

机构信息

Department of Diagnostic Radiology, University Hospital RWTH Aachen, Germany.

出版信息

Eur Radiol. 2007 Jul;17(7):1836-41. doi: 10.1007/s00330-006-0551-4. Epub 2007 Jan 12.

Abstract

The aim of this study was to investigate the value of a real-time magnetic resonance imaging (MRI) approach for the assessment of left-ventricular-wall motion in patients with insufficient transthoracic echocardiography in terms of accuracy and temporal expenditure. Twenty-five consecutive patients were examined on a 1.5-Tesla whole-body MR system (ACS-NT, Philips Medical Systems, Best, NL) using a real-time and ECG-gated (the current gold standard) steady-state free-precession (SSFP) sequence. Wall motion was analyzed by three observers by consensus interpretation. In addition, the preparation, scanning, and overall examination times were measured. The assessment of the wall motion demonstrated a close agreement between the two modalities resulting in a mean kappa coefficient of 0.8. At the same time, each stage of the examination was significantly shortened using the real-time MR approach. Real-time imaging allows for accurate assessment of left-ventricular-wall motion with the added benefit of decreased examination time. Therefore, it may serve as a cost-efficient alternative in patients with insufficient echocardiography.