Schneider Michael, Heisel Christian, Aldinger Peter R, Breusch Steffen J
Orthopedic Surgery Department I, University of Heidelberg, Heidelberg, Germany; Orthopedic Surgery, New Royal Infirmary at Little France, Edinburgh, Scotland.
J Arthroplasty. 2007 Feb;22(2):219-26. doi: 10.1016/j.arth.2006.04.023.
For extramedullary tibial alignment in total knee arthroplasty, it is important to localize the center of the ankle mortise. Malpositioning of alignment jigs can produce varus or valgus implantation and can lead to inferior clinical and radiologic outcomes. In a cadaver study, we investigated the accuracy of palpable tendons as references for extramedullary tibial alignment in 86 anatomical specimens. To investigate tendon movement with pronation and supination in living patients, we additionally performed 10 magnetic resonance imaging scans. On average, the lateral border of the tibialis anterior tendon was measured 1 cm medial to the center of the talus. The extensor hallucis longus tendon was the most accurate anatomical landmark. Pronation had a small effect, but extensive supination can lead to tendon deviation greater than 1 cm. Our results suggest that the extensor hallucis longus can serve as a useful intraoperative reference to identify the center of the ankle mortise, particularly if marked preoperatively.
在全膝关节置换术中进行胫骨髓外对线时,确定踝关节榫眼中心的位置很重要。对线夹具位置不当会导致内翻或外翻植入,并可能导致较差的临床和影像学结果。在一项尸体研究中,我们在86个解剖标本中研究了可触及肌腱作为胫骨髓外对线参考的准确性。为了研究活体患者旋前和旋后时肌腱的运动,我们还进行了10次磁共振成像扫描。平均而言,胫骨前肌腱的外侧边缘在距骨中心内侧1厘米处测量。拇长伸肌腱是最准确的解剖标志。旋前影响较小,但过度旋后会导致肌腱偏差大于1厘米。我们的结果表明,拇长伸肌可作为术中识别踝关节榫眼中心的有用参考,尤其是术前有明显标记时。